INSTALLATION MANUAL
Connect the DOTTI IR input cable (IN) to the adapter cable (G)
and then to one of the free slots on the distributor (I) on the
power supply secondary cable; then connect the connector (L)
on the DOTTI IR output cable (OUT) to connector (M) on the
Micro12 distributor cable (H).
OPERATION:
- If DOTTI IR is set to "ON/OFF" + Dimmer switch mode, the
device switches the connected lights on and off simply by
moving the hand near the sensor or holding the hand over the
sensor to vary the brightness (Dimmer).
- If DOTTI IR is set to limit switch mode the connected lights will
be switched off when an object (such as a cupboard door)
moves into the radius of action of the device (Fig.3). Vice versa,
the connected lights are switched on when there is no object
within its radius of action.
ATTENTION
- If the external wires on the device are damaged the device
must be replaced.
EN
- Connect DOTTI IR only to a safe power supply with 12Vdc or
24Vdc stabilised voltage, and never connect it to other
electronic switches or DIMMERS of any kind.
It is not advised to connect DOTTI IR to a traditional domestic
mechanical switch.
- DOTTI IR must not be installed near heat sources or
electromagnetic fields which could alter or compromise its
operation.
WARRANTY
The warranty on the device is valid only if powered by a power
supply provided by DOMUS Line. The warranty's general terms
and conditions for this device are available at
www.domusline.com