The illustrations in this document are generic; your control appearance may be slightly different from the ones shown.
Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards.
Before connecting wires, unplug the unit or switch power off at service panel and lock service disconnecting
means to prevent power from being switched on accidentally. Always wear safety glasses and gloves while
performing these instructions.
INSTALLATION
Unplug the ventilation unit.
7
Cut a 2
/
" x 1¾" hole in a wall, at a
8
convenient location for the control.
Route a cable (type 22/4) for the
control from the unit to this hole. See
figure at right.
Temporarily place the control over the
hole and mark both mounting screw hole
positions.

Remove the control, drill both screw
holes (3/16" Ø) in wall and insert the wall
anchors (included).

Strip the end of the cable to access the 4 wires (about 3"). Strip the
end of each wire (about 1/4"). Connect the wires to the terminals,
regardless of the wire color. Note which wire color has been
chosen for each terminal. See illustration below.
VC0233

Mount the control to the wall.

Depending on the type of fresh air system installed,
perform
the
electrical
connector of the unit as per one of the four models illustrated
hereafter. For more details, refer to the installation manual of the
ventilation unit.
NOTE: To avoid miswiring, refer to the notes taken at step
to match the wire color with the right terminal.
I
U
NSTALLATION AND
READ AND SAVE THESE INSTRUCTIONS
Ø 3/16", typ.
VC0210A
12V
LED
OVR
Gnd
VC0211
connection
to
the
G
20-40-60 C
SER
UIDE FOR
!
WARNING
VC0234
NOTE: The auxiliary wall control can be used with a 3-wire
connection by removing the LED signals. This optional
wiring will not allow an installation with more than 1
auxiliary wall control to properly synchronize their LEDs
on an event requested from a peer. Only the auxiliary wall
control having requested the timer event will have the
LEDs updated accordingly.
VC0238
VC0237
VC0239
Plug the ventilation unit and test the wall control.
HOW TO USE THE CONTROL
terminal

VC0212
ONTROL
Remote 6 & 7 positions terminals
Remote 10 positions terminal
Remote 4 & 6 positions terminals
On-board terminal
The main button works following this
sequence:
• Click 1 = 20 min
• Click 2 = 40 min
• Click 3 = 60 min
• Click 4 = OFF
• and so on
The indicator lights up as per the selected
duration and the system exchanges air at
MAX speed.
12V
LED
OVR
Gnd
23849 rev. 03

Publicité

loading

Sommaire des Matières pour Venmar 41400

  • Page 1 20-40-60 C NSTALLATION AND UIDE FOR ONTROL READ AND SAVE THESE INSTRUCTIONS The illustrations in this document are generic; your control appearance may be slightly different from the ones shown. WARNING Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, unplug the unit or switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.
  • Page 2 ’ ’ 20-40-60 UIDE D INSTALLATION ET D UTILISATION DE LA COMMANDE VEUILLEZ LIRE ET CONSERVER CES DIRECTIVES Les illustrations de ce document sont générales; l’apparence de votre commande peut légèrement différer de celles-ci. AVERTISSEMENT Le branchement électrique doit être effectué par du personnel qualifié conformément aux codes et aux standards en vigueur.