Use And Maintenance - Simu CENTRIS S Manuel De L'installateur

Masquer les pouces Voir aussi pour CENTRIS S:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
5
Connection diagram (all Centris range)
- The main power line must have a safety protection in accordance with the rules of the country of use.
- The power supply circuit must be equipped with an omnipolar cutting device with an openning gap of 3 mm minimum. (EN60335-1 standard).
- Switch off the installation during connection. After connection: switch your installation on, check the direction of the operator rotation.
If the direction is not the desired one, disconnect power and invert the brown and black wires (230V power) or the red and black wires
(120V power).
- A "dead man" type control can be done only by use of an unstable switch.
6
Attaching the shutter (all Centris range)
2 mm
max.
The apron must be attached securely to the tube:
- If there is a curved plate, the links must be screwed to the curved plate and/or the motor
- If there is no curved plate, one of the links, or the 1st blade, must be screwed to the motor crown.
7
End limits adjustment (all Centris range)
7.1 - Identifying the end limits
a - Sliding end limits box cover
b & c - Removable memory rings.
d & e - Rotary adjusting wheels.
f & g - Electric switches.
h - Motor crown.
i - Guiding blades.
h
7.2 - Adjustment
- Down end limit:
1 - Put electrically the shutter to the DOWN wished position.
2 - Remove the memory ring of the right side (c).
3 - Turn the right adjusting ring (e) in the "-" direction until to activate the switch (g).
- Up end limit:
1 - Put electrically the shutter to the UP wished position. (noise of the blades i)
2 - Move the shutter down up to the floor.
3 - Remove the memory ring of the left side (b).
4 - Turn the left adjusting ring (d) 2 turns in the "-" direction (tip: mark the wheel with a pencil).
- Move the shutter up and down to check the end limits positions. If necessary, turn the adjusting
wheels in the "+" direction to increase shutter travel or in the "-" direction to decrease shutter travel.
8

Use and maintenance

- Instructions for use: refer to the command point manuals and the clutch system manual.
- The motor does not require any maintenance operations.
Problems
The motorised product is not working.
The motorised product is running without
driving the curtain.
5/5
EN
L
4
N
PE
Quick connector without screw
CHC M10 ZnBl
JZC10 ZnBl
8 mm
30 N.m
±3
a
The motor is thermal.
The clutch system is active.
230V - 50Hz
120V - 60Hz
Blue
N
Brown
L1
Black
L2
Green / yellow
PE
f
b
d
Possible causes
White
Black
Red
Green
i
x 5
x 1
1
=
=
7.3
Solutions
Wait until the motor cools down.
Check that the clutch cable is not wound up or
that the clutch lever is deactivated.
OK
1
2
3
8 mm
30 N.m
±3
g
c
e
2,5°
CBL Z 3x12 screw

Publicité

Table des Matières
loading

Table des Matières