INSTALLATION MANUAL
ARD2/12
Rectified and filtered PSU
PRODUCT PRESENTATION
Designed for locking devices
with electromagnetic locks.
Rectified, filtered and not regulated PSU.
Primary and secondary inputs
protected by automatic fuses.
Additional AC output.
Input voltage: 230V ± 10%, 50/60 Hz.
Max power consumption : 0.16A.
2 outputs:
- Main 12V dc rectified and filtered
and non-regulated.
- Additional 12Vac.
Maximum load current:
- 12V dc output / 1.5A (nominal), 2A (peak),
- 12V ac output / 0.3A.
Wall fixing (screw and plastic anchor included)*
Inputs and outputs protected by resettable fuses.
(After an overload or short-circuit, disconnect
the network for 1 minute to reset the fuse.)
TERMINAL
VOLTAGE
BLOCK OUTPUTS
1
12V ac
2
12V ac
7 - 8
0V dc
9 - 10
+12V dc
N
230V ac
L
230V ac
COMPLIANT WITH EUROPEAN STANDARDS
EN 55022
EN 61000-4-2
EN 61000-3-2
EN 61000-4-3
EN 61000-3-3
EN 61000-4-4
This product must be installed in accordance
with the local safety standards.
cdvi.com
2
cdvigroup.com
*Wall fixing
N
L
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
on each side
WEEE & RoHS
IP20
Mains terminal block cover in the event of mounting
outside a standard electrical equipment box.
CE compliance
-25°C to +55°C