Procedure to Replace Reactor Cell:
1. Open filter case and loosen 2 screws at
top.
2. Detach 4 rubber feet and loosen 4 screws.

Important:

After replacing reactor cell, press and hold the power button on the body for 10 seconds.
This resets the operation time to zero.
How to Maintain and Clean the IAQ Sensor
The IAQ sensor is a very delicate instrument that uses light scattering to detect pollution.
It therefore needs a clean lens to work effectively. Regular maintenance (every 6 months)
should be carried out to keep the lens clean. Important – Only use pure water and allow to
dry completely before replacing. To avoid damage to the plastic lens do not use chemicals
such as benzene or alcohol (found in some cleaning products).
Procedure to maintain and clean the IAQ Sensor:
1. Open the body as shown in the previous image.
2. Detach wire connector attached to IAQ sensor.
3. Clean lens with a clean cotton swab dampened
with pure water.
4. Dry lens and IAQ sensor.
5. Assemble in reverse order.
Caution:
• Do not place in direct sunlight.
• Do not spray water or perfume near the sensor.
3. Open the body and loosen 4 screws
surrounding Reactor Cell.
4. Detach wire connector.
5. Replace with new reactor cell and assemble
in reverse order. The used reactor cell is fully
recyclable, as a consumer it is your responsi-
bility to ensure it is disposed of properly.
9