HSI 150-DFK
7
Installation
The outside of the building must be level and clean
prior to installation!
Centre the flange over the existing opening. Align horizon-
1
tally using the integrated level and mark the dowel holes.
Then drill the dowel holes (� 10 mm, 80 mm deep), clean,
2
and install the dowels.
If the surface is uneven, a coating of Sikaflex-11C (not
3
included in scope of delivery) must also be applied in the
preformed seal recesses at the rear of the flange.
Following this, press the flange onto the wall and use the
4
pre-installed screws to insert the fastening dowels and
sealing rings until the dowel shaft is inside the flange base
and is flush with the surface of the wall.
Tightening torque for concrete: up to 12 Nm
Tightening torque for masonry: 6 Nm
Fastening elements for installation on metal housings
are not included in the scope of delivery.