PROBLEM: Pulsing Alarm
Reason
Input voltage below 10.5V
Poor or weak battery condition.
Poor or loose cable connection.
Inadequate power being delivered to
the inverter or excessive voltage drop.

DISPOSAL/RECYCLING OF INVERTER

Electronic products are known to contain materials that are toxic if improperly
disposed. Contact local authorities for disposal and recycling information.
SPECIFICATIONS
All specifications are typical at nominal line, half load and 77ºF unless otherwise
noted. Specifications are subject to change without notice.
Input
AC Output
Output frequency
Output waveform
TrueRated
Power
(24-hour continuous)
Peak Surge
11
Solution
Keep input voltage above 10.5V
Recharge or replace battery.
Inspect terminals and tighten all
connections.
Use heavier gauge DC cable.
Keep cable length as short as
possible.
11-15V DC Input
110-120V
60Hz
± 1.5Hz
Modified Sine Waveform
425 Watts
Watts
825
www.wagan.com
®