13. Use the exterior mounted hinges to allow the door to swing at
a wider angle and to allow the board to swivel.
NOTE: Swiveling of the board may be restricted depending
on the type of door hinge used.
14. See "Make Electrical Connections" section for final wiring
directions.

Recessed Mounting

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
The ironing station unit extends into the room approximately
7¹⁄₂ in. (19.1 cm).
1. Determine the desired ironing board height above the floor
using the chart in the "Location Requirements" section. Care
should be taken to ensure the unit will be mounted at the
ironing board height desired.
2. Using a stud finder, locate the wall studs to be used for
mounting.
3. Locate the existing wiring in the wall to prevent drilling into or
severing a wire or other hidden utilities during drilling.
4. Cut a hole in the drywall large enough for the ironing station
to fit. The dimensions of the ironing station unit are 14¹/₂ in.
(36.8 cm) x 47¹/₂ in. (120.7 cm) x 11¹/₂ in. (29.2 cm).
5. Allow at least 16 in. (40.6 cm) to the side of the unit for the
door to swing open. Door opens approximately 180 degrees.
See "Install Door."
6. Attach 2 in. (5.1 cm) x 4 in. (10.2 cm) cross supports between
the studs, level with the the bottom of the opening.
1
2
1. Studs
2. Cross support - 2 in. x 4 in.
(5.1 cm x 10.2 cm)
7. Shim the side walls to match the width of the ironing station.
8. Using a ¹/₄ in. drill bit, predrill the pilot holes through the unit
frame as indicated in the graphic below.
NOTE: Drill slowly or add backing piece to prevent chipping
of the cabinet interior.
2"
(5.1 cm)
1
1
(3.8 cm)
LEFT SIDE
INTERIOR
BACK
9. Remove the two screws from the cover of the electrical
junction box located in the bottom section of the cabinet.
NOTE: Pigtails are provided inside of the junction box located
underneath the lower shelf for hookup to the supply line.
10. Remove the knockout for the appropriate wiring entrance
location.
NOTE: For recessed mounting, the wiring will enter from the
bottom of the ironing station unit.
11. Before putting the unit into place, install a strain relief in the
location where the knockout was removed.
12. Make sure the supply wire is in a location to thread through
the wiring opening in the ironing station approximately from
the bottom of unit. A free wire length of 5 ft (152.4 cm) is
recommended.
2
1
2
1
/
"
8
(5.3 cm)
16"
(40.6 cm)
2"
(5.1 cm)
/
"
1
1
/
"
2
2
(3.8 cm)
18
1
/
"
2
(47 cm)
RIGHT SIDE
INTERIOR
BACK
1
1
/
"
2
(3.8 cm)
2"
(5.1 cm)
BACK
/
" (5.3 cm)
8
FRONT
5

Publicité

Table des Matières
loading

Table des Matières