System Event
Zone tamper restore (##)
Keypad Lockout
AC Failure
Battery Failure
Auxiliary supply trouble
Bell output current limit
Bell absent
Clock lost
Fire loop trouble
TLM trouble restore
AC Failure restore
Battery Failure restore
Auxiliary supply trouble restore
Bell output current limit restore
Bell absent restore
Clock programmed
Fire loop trouble restore
Combus fault
Module tamper
Module ROM_RAM_error
Module TLM trouble
Module fail to communicate to monitoring station
Printer fault
Module AC Failure
Module battery failure
Module Auxiliary supply trouble
Combus fault restore
Module tamper restore
Module ROM_RAM_error restore
Module TLM restore
Early to Arm by User
Late to Arm by User
Zone Excluded on Force Arming
Zone Went Back to Arm Status
Printer fault restore
Module AC restore
Module battery restore
Module Auxiliary supply restore
Fail to communicate with monitoring station
Module RF low battery
Module RF supervision trouble
Module RF battery restore
Module RF supervision restore
Cold Start
Warm Start
Test Report engaged
Listen-In request
WinLoad Login request
PC software communication finished
Installer on site
Installer programming finished
Module Fail to Communicate Restore
Default Contact ID Report Code
when using sections [4032] to [4037]
3 144 - Sensor tamper restore
1 421 - Access denied
1 3A1 - AC loss
1 3A9 - Battery test failure
1 3AA - System trouble
1 321 - Bell 1
1 321 - Bell 1
1 626 - Time/Date inaccurate
1 373 - Fire trouble
3 351 - Telco 1 fault restore
3 3A1 - AC loss restore
3 3A9 - Battery test restore
3 3AA - System trouble restore
3 321 - Bell 1 restore
3 321 - Bell 1 restore
3 625 - Time/Date Reset
3 373 - Fire trouble restore
1 333 - Expansion module failure
1 145 - Expansion module tamper
1 3A4 - Rom checksum bad
1 352 - Telco 2 fault
1 354 - Fail to communicate
1 336 - Local printer failure
1 3A1 - AC loss
1 3A9 - Battery test failure
1 3AA - System trouble
3 333 - Expansion module failure restore
3 145 - Expansion module tamper restore
3 3A4 - Rom checksum bad restore
3 352 - Telco 2 fault restore
3 451 - Early to Close
3 452 - Late to Close
1 57A - Zone Bypass
3 57A - Zone Bypass Restore
3 336 - Local printer failure restore
3 3A1 - AC loss restore
3 3A9 - Battery test failure restore
3 3AA - System trouble restore
1 354 - Fail to communicate
1 384 - RF transmitter low battery
1 381 - Loss of supervision - RF
3 384 - RF transmitter battery restore
3 381 - Supervision restore - RF
1 3A8 - System shutdown
1 3A5 - System reset
1 6A2 - Periodic test report
1 606 - Listen-In to follow
1 411 - Call Back Request
1 412 - Successful - download access
1 627 - Program mode Entry
1 628 - Program mode Exit
3 354 - Fail to Communicate Restore
Default SIA Report Code
when using sections [4032] to [4037]
TR - Tamper Restoral
JA - User Code Tamper
AT - AC Trouble
YT - System Battery Trouble
YP - Power Supply Trouble
YA - Bell Fault
YA - Bell Fault
JT - Time Changed
FT - Fire Trouble
LR - Phone Line restoral
AR - AC Restoral
YR - System Battery Restoral
YQ - Power Supply restored
YH - Bell Restored
YH - Bell Restored
JT - Time Changed
FJ - Fire Trouble Restore
ET - Expansion Trouble
TA - Tamper Alarm
YF - Parameter Checksum Fail
LT - Phone Line trouble
YC - Communication Fails
VT - Printer Trouble
AT - AC Trouble
YT - System Battery Trouble
YP - Power Supply Trouble
ER - Expansion Restoral
TR - Tamper Restoral
YG - Parameter Changed
LR - Phone Line Restoral
CK - Early to Close
CJ - Late to Close
XW - Zone Forced
VV - Zone Included
VR - Printer Restore
AR - AC Restoral
YR - System Battery Restoral
YQ - Power Supply Restored
YC - Communication Fails
XT - Transmitter Battery Trouble
US - Untype Zone Supervision
XR - Transmitter Battery Restoral
UR - Untyped Zone Restoral
RR - Power Up
YW - Watchdog Reset
TX - Test Report
LF - Listen-In to follow
RB - Remote Program Begin
RS - Remote Program Success
LB - Local Program
LS - Local Program Success
YK - Communication Restore
Panneau de contrôle EVO 47