APPLICATION
Audible alarm compatible with BG24DCW/BG24DCG models. This comes
standard in the Parking model, or PBG24DCW/PBG24DCG.
FUNCTIONS
The alarm when installed and enabled through the control board interface
will sound an alarm when the arm is triggered for motion.
ASSEMBLY
Alarm is simple and mounts internally to threaded posts in the operator. It
has a harness that connects to the main board.
TASKS
Disconnect electric power to the operator.
INSTALL BGALARM
1. Loosen the four (4) nuts on the side of the PCB tray and rotate the PCB
tray upwards (figure 1).
2. Mount the alarm to the two (2) operator studs and secure with two (2) nuts.
3. Route the wire harness to the main board and secure the wire harness
with the PCB tray cable holders.
4. Connect the harness to the main board connector (figure 2).
5. Tighten the four (4) nuts on the side of the PCB tray.
6. Restore power to the operator.
Figure 1
Figure 2
STOP / BACK
114-6007-000
CONNECTIVITY
MODULE
OPEN
CLOSE
STOP
COMMON
FIRE DEPT OPEN
COMMON
EXIT
COMMON
SHADOW
COMMON
CLOSE EYES / INTERRUPT
COMMON
ENTER
CLOSE EDGE
COMMON
OPEN EYES / EDGE
COMMON
RELAY N. O.
COMMON
RELAY N. C.
COM LINK A
COM LINK B
ACCESSORY
PWR ON
COMMON
CLASS 2 SUPPLY
24 VOLTS DC
ACCESSORY
PWR SWITCHED
COMMON
To prevent possible SERIOUS INJURY or DEATH, disconnect electric
power to operator BEFORE installing. ALL electrical connections MUST be
made by a qualified individual.
WARNING: This product can expose you to chemicals including
lead, which are known to the State of California to cause cancer or
birth defects or other reproductive harm. For more information go
to www.P65Warnings.ca.gov.
ACTIVATE BGALARM
1. Select Enter to navigate to the
Main Menu > Alarm (figure 3).
2. Select preferred mode: ON/OFF
and > to set (figure 4).
3. There will be a display to confirm
selection. Exit screen to navigate
back to Main Menu (figure 5).
PACKING LIST
Qty.
Description
1
Alarm
1
Wire harness
2
Nuts
LiftMaster and the LiftMaster logo are trademarks, service marks, and/or
registered trademarks of The Chamberlain Group LLC. All rights reserved.
The Chamberlain Group LLC, 300 Windsor Drive, Oak Brook, IL, 60523, United States
1
BGALARM ACCESSORY
INSTRUCTIONS
WARNING
©2024 The Chamberlain Group LLC
Figure 3
Figure 4
Figure 5