IMPORTANT INSTRUCTIONS

PLEASE READ ALL INSTRUCTIONS
BEFORE USING THIS HEATER
When using electrical appliances, basic precautions should
always be followed to reduce risk of fire, electrical shock and
injury to persons or property, including the following:
1.Read all instructions before using this heater.
2.This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes and
curtains at least 3 ft. (0.9 meters) from the front and top of the
heater and keep them away from the sides and rear.
3.Extreme caution and reasonable supervision is necessary
when any heater is used by or near children, invalids or pets
and whenever the heater is left operating and unattended.
4. Always switch off the heater when not in use.
5. Do not operate any heater after the heater malfunctions, has
been dropped or damaged in any manner. Disconnect power
at service panel and have heater inspected by a qualified
electrician before reusing.
6. Do not use outdoors.
7. To disconnect heater, turn off power to heater circuit at main
disconnect panel.
8. Do not install less than 6 feet (1.8 m) high from the floor and
closer than 1 foot (0.3 m) to any adjacent vertical surfaces or
walls. Keep at least 4.5 inches (11.5 cm) from the back wall
(with or without using the wall hanging mounting bracket).
B
C
D
G
INSIDE
WALL
THERMOSTAT
THERMOSTAT
H
A
E
F
MAX
ON
POWER
OFF
OFF
TEMPERATURE SETTING
J
I
K
Traces of smoke or odor when unit is initiated indicates that small
amounts of oil leaked on heating coil during manufacturing. It will
evaporate quickly and should not re-occur. Make sure the appli-
ance location is well ventilated during operation. It is normal for the
unit to emit sounds when turned on for the first time.
Make sure that the room in which the appliance is located is well
ventilated during this operation.
9.Do not insert or allow foreign objects to enter any ventilation or
exhaust opening as this may cause an electric shock or fire, or
damage the heater.
10.To prevent a possible fire, do not block air intakes or exhaust
in any manner.
11.A heater has hot and arcing or sparking parts inside. To reduce
the risk of fire, do not use it in areas where gasoline, paint, or
flammable vapors and liquids are used or stored.
12.Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electric
shock, or injury to persons.
13. This product must be installed by a certified electrician, in
accordance with local codes.
14. For supply cables, use 6 AWG (13.3 mm2) copper wires .
RISK OF FIRE, DO NOT USE AS A
RESIDENTIAL OR HOUSEHOLD
L
A. Wall Mount Bracket
B. Ceiling Bracket
C. Upper Housing
D. Louver for air direction
E. Tilt adjustable knob
F. Lower Housing
G. Front Exhaust Grill
H. Select switch for built-in Thermostat or Wall
Thermostat
I. Inspection window (Inspection cover)
J. ON/OFF Switch
K. Thermostat knob
L. Wiring access window (wire connection cover)