EUROPE 205
Advice before Use
Read carefully these instructions.
As soon as the equipment is delivered, open packings and inspect
the equipment carefully.
If you notice any damage, contact immediately the transport
company and register your complaint in due form with mention of
the defects.
Be sure that this equipment left our factory in perfect condition.
Check if the received equipment is consistent with the delivery
notice and if this delivery notice is consistent with your order.
If it is not, contact immediately your supplier.
General Remarks
This luminaire is a lighting equipment designed for professional use
only in theatres and indoor television or movie studios.
Designed and built in accordance with EN 60950 safety regulations, it
must imperatively be connected to earth by means of its earth wire.
It also complies with the CEI safety regulations
(598-1/598-2-17 publications).
To prevent any electrical shock, there is no need to open this equipment
when functioning.
Nevertheless:
Any part or lenses have to be replaced if they are visibly damaged
and their efficiency might be reduced, for example in case of deep
cracks or scratches.
Lamp must be changed if damaged or distorted by heat.
If internal access is needed for control, service or repair purposes,
always refer to qualified personnel.
In all events, always unplug the power supply cable before opening,
LETHAL VOLTAGE PRESENT INSIDE
It is the user's responsibility to use the luminaire for its intended purpose
and to check the equipment that might be connected to it.
The luminaire can under no circumstances be modified.
ADB will not assume any responsibility in case of damage resulting from
modications made to the luminaire.
This luminaire is a piece of professional equipment designed for easy
and simple use. Nevertheless, always refer to qualified personnel for
any installation or repair work.
Important Remark
Power supply cables and other connections are essential for your
equipment and contribute greatly to a safe and trouble free operation.
Always hold the plug when disconnecting a cable, never pull the
cable.
Never use cables or connectors in bad condition, check them
before installation and periodically thereafter.
Never tie power supply and data cables together.
Page 6
Beam Shaping Shutters Insertion
Fitting the Lamp
Type of lamp to use
GY16 lampholder 2 kW lamp.
Light centre lenght (LCL) shall be 70 mm
Unplug luminaire power supply cable.
Open the access door to the lamp and position the lamp carrier
back by means of the fine adjustment knob.
Plug the lamp into the socket (GY16 lampholder), close the door
and connect the power supply cable.
Notes:
For optimal lamp performance, please refer to the manufacturer's
notice.
The lamp must be changed if damaged or distorted by heat.
Electrical Connection
This luminaire is designed for operating at a nominal voltage of 220 - 240 V.
It is supplied with a 2 m silicone power supply cable
2
(3 x 1.5 mm
section) fitted with a high temperature CEE22 receptacle
on the luminaire side.
Use IMPERATIVELY this cable with your luminaire.
For your own safety, make sure the earth wire (yellow-green) is
ALWAYS connected to earth.
Plug the cable into the power supply socket at the back end of the
luminaire.
Secure the power plug with the stirrup.
Insert shutters
as described
opposite, start
with
corners
marked
with
«X».
Lighting Technologies