JB Systems Light CYCLOPE Mode D'emploi page 4

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
ENGLISH
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
 The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may result in overheating.
 The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
DESCRIPTION:
1. Mains output with IEC socket: you can use a special IEC power cable to connect this output with the
mains input of the next CYCLOPE for easier linking. (max 20 units can be linked)
2. DMX input
3. DMX output
4. ¼" Jack input for the optional CA-8 hand controller
5. Internal microphone
6. Hanging bracket with 2 knobs on both sides to fasten the unit and a mounting hole to fix a mounting
hook.
7. Slave LED: is lit when the unit is in slave mode
8. Sound LED: blinks to the rhythm of the music while the unit is in audio mode
9. DMX LED: is lit when the unit receives a DMX-signal
10. Master LED: is lit when the unit is switched as master
11. MENU button: used to select the different menu items
12. DOWN button: to go back in the menu and to lower the values shown on the display.
13. UP button: to go up in the menu and to increase the values shown on the display.
14. ENTER button: used to confirm your choice.
15. DISPLAY shows the various menus and the selected functions.
JB SYSTEMS
®
OPERATION MANUAL
3/54
CYCLOPE
ENGLISH
HOW TO SETUP:
MAIN MENU:
 To select any of the menu options, press the MENU button up to when the required one is shown on the
display.
 Select the function with the ENTER button. The display will blink.
 Use DOWN and UP button to choose the desired menu option.
 Once the required menu option is selected, press the ENTER button to select. To go back to the functions
without any change press the MENU button or just wait 8 seconds. The menu structure is shown below.
DMX512 Address Setting
Used to set the starting address in a DMX setup.
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP buttons to change the DMX512 address.
 Once the correct address shows on the display, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Channel Mode
 Press the MENU button until
is
shown on the display.
 Press the ENTER button, the display starts
blinking.
1ch
 Use DOWN and UP button to select the
(1 Channel ),
(4 Channel ) or
(10 Channel) mode.
 Once the mode is selected, press the
ENTER button to setup
(or automatically return to the main functions
without any change after 8 seconds)
To go back to the functions without any change
press the MENU button again.
Working Mode
Used to set the unit in master or slave
mode.
 Press the MENU button until
is
shown on the display.
 Press the ENTER button, the current working
mode starts blinking in the display
 Use the DOWN and UP buttons to select
(master),
(slave in sync with
the master) or
(2 light show – slave in
anti-sync with the master).
 Once the mode is selected, press the
ENTER button save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Remarks: when "SL 1" or "SL 2" is selected, some menu options are not available. When only one unit is
used, you should always select master mode.
JB SYSTEMS
®
OPERATION MANUAL
4/54
CYCLOPE

Publicité

Table des Matières
loading

Table des Matières