Page 2
MODELS MUA006A • MUA008A • MUA010A Page 2 AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER & PRESSURE SWITCH READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY CAUTION WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 1. Do not locate outside air inlet near hazardous materials or explosives.
MODELS MUA006A • MUA008A • MUA010A Page 3 PLAN THE INSTALLATION MINIMUM RETURN AIR TEMPERATURE REQUIREMENTS Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestions for the most HVAC equipment manufacturers may have minimum requirements for effective installation approach by considering a few important factors.
MODELS MUA006A • MUA008A • MUA010A Page 4 TYPICAL INSTALLATIONS Installations will vary according to the location in the home where the unit is installed and which model Damper is used. Use the following illustrations and notes as guidance for your own installation. Always comply with local code requirements and in any instance where a detail shown below conflicts with local code, the local code provision shall apply.
Page 5
The pressure switch is designed to operate when the static pressure increases to 0.05” Ps or more. It may not operate at low speeds since the pressure is below this limit. MULTIPLE DAMPERS More than one damper may be required to balance the system. If more than one is required use (1) MUA006A, MUA008A, or MUA010A and then use the 54060012 (6”), 54060013 (8”), or 54060014 (10”) dampers as additional dampers. https://manual-hub.com/...
Page 6
MODELS MUA006A • MUA008A • MUA010A Page 6 LOCATION OF PROBE AND PRESSURE SWITCH The probe must be mounted between the range hood damper The pressure switch should be mounted so it is accessible for and the wall cap, roof cap, in-line blower or external blower.
Page 7
MODELS MUA006A • MUA008A • MUA010A Page 7 MOUNTING POSITIONS OF PROBE & PRESSURE SWITCH DUCTWORK DUCTWORK FLOW PRESSURE PRESSURE SWITCH SWITCH PROBE TUBING (air flow arrow TUBING pointing in direction of air flow) PROBE DUCTWORK (air flow arrow HORIZONTAL...
MODELS MUA006A • MUA008A • MUA010A Page 8 WIRE THE SYSTEM Wire the system as shown. MAKE-UP AIR DAMPER MAKE-UP AIR DAMPER MAKE-UP AIR DAMPER WIRING DIAGRAM TRANSFORMER TRANSFORMER MULTIPLE DAMPERS PRESSURE PRESSURE SWITCH SWITCH BLACK (LINE) BLACK (LINE) WHITE (COMMON)
MODELS MUA006A • MUA008A • MUA010A Page 9 MAINTENANCE 4. How do I know if I need make-up air for my Regular maintenance is necessary to ensure the proper operation range hood? of the Damper system. Failure to conduct such routine maintenance...
MODÈLES MUA006A • MUA008A • MUA010A CLAPET AUTOMATIQUE D’AIR DE Page 12 COMPENSATION AVEC TRANSFORMATEUR ET MANOCONTACTEUR LIRE CES DIRECTIVES ET LES CONSERVER POUR USAGE RÉSIDENTIEL SEULEMENT ATTENTION AVERTISSEMENT OBSERVEZ LES DIRECTIVES CI-DESSOUS AFIN DE RÉDUIRE 1. Ne situez pas la prise d’air extérieur près de matières dangereuses LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE...
MODÈLES MUA006A • MUA008A • MUA010A PLANIFICATION Page 13 DE L’INSTALLATION La planification de l’installation exige d’abord le choix du mode EXIGENCES RELATIVES À LA TEMPÉRATURE MINIMALE DE d’installation le plus approprié. Le tableau ci-dessous présente des L’ A IR DE RETOUR suggestions pour le type d’installation le plus efficace compte tenu...
MODÈLES MUA006A • MUA008A • MUA010A Page 14 INSTALLATIONS TYPE Les installations varieront en fonction de l’emplacement de l’appareil dans la maison et du modèle de clapet utilisé. Consultez les illustrations et notes ci-dessous pour vous guider dans l’installation. Respectez toujours les exigences des codes dans toute situation où...
CLAPETS MULTIPLES Plusieurs clapets peuvent être nécessaires pour équilibrer le système. Si vous utilisez plusieurs clapets, choisissez un (1) clapet MUA006A, MUA008A, ou MUA010A puis utilisez les modèles 54060012 (6 po), 54060013 (8 po), ou 54060014 (10 po) comme clapets additionnels.
MODÈLES MUA006A • MUA008A • MUA010A Page 16 EMPLACEMENT DE LA SONDE ET DU MANOCONTACTEUR La sonde doit être installée entre le clapet de la hotte et le Le manocontacteur doit être placé à un endroit accessible capuchon mural, le capuchon de toit, le ventilateur intermédiaire pour un entretien éventuel.
MODÈLES MUA006A • MUA008A • MUA010A Page 17 POSITIONS DE MONTAGE DE LA SONDE ET DU MANOCONTACTEUR CONDUIT CONDUIT DÉBIT D'AIR MANOCONTACTEUR MANOCONTACTEUR SONDE TUBE (la flèche TUBE pointe dans le sens du SONDE débit d’air) CONDUIT (la flèche pointe dans HORIZONTAL DÉBIT...
MODÈLES MUA006A • MUA008A • MUA010A Page 19 ENTRETIEN un débit de 300 pieds cubes par minute (pi /m) ou plus exigent un Un entretien régulier est nécessaire pour garantir le bon dispositif mécanique d’apport d’air de compensation. Dans d’autres cas, fonctionnement du système de clapet.