PREPARE THE HOOD

Unpack hood and check contents.
You should receive:
1 - Hood
2 - Decorative Flue Assembly
1 - Parts Bag containing:
2 - Flue Mounting Bracket
2 - Mounting Screws (M3 x 8mm Pan Head)
2 - Mounting Screws (M4 x 8mm Round Head)
2 - Mounting Screws (ST4 x 12mm Self Tapping)
2 - Mounting Screws (ST4 x 35mm Self Tapping)
4 - Drywall Anchors ( 6 x 30mm and 8 x 35mm)
1 - Installation Instructions

DUCTING

Determine whether the hood will discharge vertically or
horizontally. For vertical or horizontal discharge, run ductwork
between the hood location and roof cap or wall cap.
A minimum 6" round duct must be used to maintain maximum
airflow efficiency.
Always use rigid type metal ducts only.
Whenever possible reduce the number of transitions and turns
in the ductwork. If a long duct run is required increase the duct
size from 6" to 7".
If elbows or bends are required; install as far away from the
hood as possible.
Minimum mounting height between the range and the bottom
of the hood should be no less than 26".
Maximum mounting height between the range and the bottom
of the hood should be no more than 34".
ROOF CAP
DECORATIVE
FLUE
HOOD
26"~34"ABOVE
COOKING
SURF ACE
ROUND
DUCT
WA LL CAP
ROUND ELBOW
6" ADAPTER
WARNING!
FIRE HAZARD
1. NEVER implement ductwork in a space between walls, crawl
spaces, attics or garages. All exhaust must be vented outside.
Use metal ductwork only. Fasten all connections with sheet
metal screws and certified silver tape or duct tape.
2. Use the following diagram for placement of ductwork and
electrical cutout in cabinet. For a non-ducted installation, DO
NOT cut a duct access hole.
MOUNTING TO THE WALL
1. Before mounting the hood, plug in and test all functions
for proper operation.
2. Remove the filters from the bottom of the hood to prevent
damage during the installation.
3. With assistance, hold the hood in position temporarily
ensuring the bottom is above the minimum clearance
from the cooking surface. Mark on the wall the location for the
holes for the two mounting screws.
4. Drill the holes (A) at the distances indicated. Use the
appropriate screws and screw anchors for your wall type (e.g.
reinforced concrete, drywall, etc.). If necessary, prepare back
wall with cross framing for secure installation.
5. Mount the hood on the wall screws. Align it in a horizon-
tal position relative to cabinets. When the hood has been
adjusted, secure unit by tightening screws (A).
6. Connect a 6" aluminum duct tube (not included) to
the exhaust piece using duct tape on all seals. (C).
Refer to diagram on following page.

CONNECT DUCTWORK

1. Carefully loosen but do not separate the telescopic chimney
duct pieces.
2. Install the electrical power supply within the parameters of the
decorative chimney duct.
3. Adjust the width of the support bracket to match the upper duct.
Attach it to the ceiling using the screws (B) so that it is centered
in line with your hood and at a distance from the ceiling indicated.
3
8-5/16"
B
9"
A