Page 1
White-Rodgers P.O. 6977 9797 Reavis Road St. Louis, Missouri 63123 EMERSON IOC17E - 41000 ELECTRONIC CLEANER OPERATION INSTALLATION MANUAL Printed in U.S.A. Form No. 846-0290-Rev.
Page 2
Ill. INSTALLATION A. Exploded View Placement ..B. Parts List Ceiling Mounting C. Ordering Information Electrical Wiring . SPECIFICATIONS NAME: Emerson Self-Contained Flush- Mount Elec- DIMENSIONS: tronic Air Cleaner TOTAL AMP DRAW: 2.2 Amps MODEL: IOC17E-41000 VARIABLE SPEED: To 1000...
Page 3
B. SPECIFICATIONS The Air Cleaner takes its energy saving power WEIGHT: 78 lbs. requirements (approx. 154 watts) from standard SHIPPING WEIGHT. 86 lbs. (42kg) electrical wiring systems. No special provisions are C. EFFICIENCY required. Local residential and commercial wiring codes apply.
Page 4
SIZING CHART FOR YOUR CLEANER BARS CAFETERIAS LUNCHEONETTES BOWLING CENTERS RESTAURANTS PLACES ASSEMBLY STORES OFFICES Capacity is 1000 cfm/ 1075 1610 2150 2690 3230 3760 4300 60,000 cf/hr. [501 (100) (200) [2501 13001 (3501 14001 AREA IN SQUARE FEET [SQUARE METERS IN BRACKETS) The number of air changes per hour determines hour than recommended...
Page 5
Ill. INSTALLATION A. PLACEMENT The installer must be qualified to make approved electrical c onnections anda safeceilinginstallation with attention to the best placement as shown in the following drawings. The electronic Air Cleaner should be mounted in the ceiling grid % of the room length awayfrom the wall. 23 3/4 Air is drawnthru the straightvanedgrille and discharg- ed thru the angled grille which should be directed...
Page 6
lv. MAINTENANCE/WASHING B. IONIZING WIRE REPLACEMENT A. WASHING CELL The fine tungsten ionizing wire in the charging When to Wash: Periodically the dirt collected section of the electronic cell may break or become your unit must be removed.The frequency of wash- damaged.
Page 7
An ionizing-collectingcell that hasbeendamaged, 1. Damaged (bent) plates - Straighten or replace. wherein the designedspacingbetweenelectrically Loose ionizing wires - Repair or replace. charged and ground components has been decreas- ed, may also produce an abnormal amount of ozone. Dirty Cell - Clean. CHECK LIST FOR ABOVE: Check...
Page 8
QUICK REFERENCE TROUBLE CHART CONDITION TROUBLE PROBABLE SYMPTON DESCRIPTION LOCATION PROBABILITY POSSIBLE CAUSE CORRECTION Remove& Replace Broken Ion Wire Excessive Dirt Wash Short Remove Indicating Cell Good Object Between Plates Straighten or Replace Light Ci rcuit Damaged (Bent) Plates Damaged(Bent)Ionizer Straighten or Replace Broken Insulator...
Page 9
VI. ELECTRICAL TROUBLE SHOOTING WARNING: Do not attempt to Install this air cleaner unless you are completely famlllar with the necessary tools, equipment, utlllty connec- tions and potential hazards involved. We ask that you contact a reliable heating and alr condltlon- Ing dealer or other qualified Installer to install this unit.
Page 11
If the installing dealer or contractor fails to render performanceunder the terms of this Limited Warrantywithin a reasonabletime, then contact in writing: WHITE-RODGERS DiViSlon Of Emerson Electric 9797 Reavis Road, SL Louis, MO 63122. (314) 577-1»o The consumermay be askedto return the air cleaner or part (s)claimed to be defectiveto White-Rodgers,303 North IndustrialPark Rd., Harrison,Arkansas 72601or nearest distributorpoint, at the expenseof the•consumer.The consumer will be expectedto supply informationon serial number,dateof installation,...
Page 12
WHITE-RODGERS White-Rodgers Division, Emerson Electric Co. 9797 Reavis Road, St. Louis, MO 63123 (314) 577-1300...
Page 13
White-Rodgers P.O. 6977 9797 Reavis Road St. Louis, Missouri 63123 EMERSON IOC17E - 41000 PURIFICATEUR D'AlR ELECTRONIQUE MANUEL D'INSTALLATION ET D'USAGE Imprimé aux E.-U. Form no 846-0290 Rev.
Page 14
électronique autonome ä DIMENSIONS: 47-3/4" x 23-3/4" x 15" montage en affleurement Emerson APPEL TOTAL DE COURANT: 2.2 amp. MODELE: IOC17E-41000 VITESSE VARIABLE: 200 ä 1000 pi3/min. TENSION ET FRÉQUENCE: c.a. 120volts, nominal, 60 cycles l. INTRODUCTION A. COMMENT...
Page 15
B. SPÉCIFICATIONS POIDS: 78 lb Le purificateur recoit ses exigences d'alimentation POIDS D'EXPÉDITION:86 lb (42kg) d'épargne d'énergie des systömes électriques ordin- C. EFFICACITÉ aires (environ 154watts). Pasde prévisions spéciales requises. Les codes de cäblage résidentiels L'efficacité varie selon vitesse ventilateur commerciaux Iocaux s'appliquent.
Page 16
Les informations le nombre requis ont été des applications. Utilisez ces informations comme obtenues du manuel ASHRAE Handbook of Funda- guide. Nous vous encourageons å utiliser votre mentals, 1985; du manuel ASHRAE Guide and Data expérience et votre jugement ä l'application de ces Book, Application,...
Page 17
EXEMPLE 3 - CHOIX DU NOMBRE D'UNITÉS Solution: LE NOMBRE D'OCCUPANTS 75 personnes x 35 pi3/min. (1m3/min.) par personne Un salan å cocktails a en moyenne 75 occupants. = 2625 pi3/min (75m3/min.). Utilisant le minimum ASHRAE recommandé de 35 2625 (75) = 2.6 (2 ou 3 unités) pi3/min.
Page 18
lv. ENTRETIEN/LAVAGE B. REMPLACEMENT FILS A. LAVAGE CELLULE D'IONISATION Quand Ia laver: Périodiquement, la saleté captée par votre unité doit étre enlevée. La fréquence Les fils d'ionisation fins en tungsten dans la section lavages dépendra du montant de saleté présent dans d'ionisation de Ia cellule électronique...
Page 19
une cellule collectrice/d,ionisation qui a été 1. Des plaques endommagées (pliées) - Redressez- endommagée oü l'espacement prévu entre les les ou remplacez-les. composants chargés d'électricité et ceux å la masse 2. Des fils d'ionisation desserrés - Réparez-les ou a été diminué, peut aussi produire un montant remplacez-les.
Page 20
Liste de vérification pour bruits d'étincelles et de sifflement: (X) Etincelle (O) Sifflement Fil(s) d'ionisation desserré(s) - Réparez ou remplacez. Composants de la cellule excessivement sales - Nettoyez. Plaques d'ionisateur endommagées (pliées) - Redressez ou remplacez. Fil ou ensemble de contact de tension défectueux ou desserré...
Page 21
VI. RECHERCE ENNUIS ÉLECTRIQUES ATTENTION!!!! LE PROCÉDÉ DE REPARATION SUIVANT EXPOSE LES PIECES SOUS HAUTE TENSION ET NE DEVRAIT ETRE EFFECTUÉ QUE PAR UN PERSON- NEL QUALIFIÉ!! LES RACCORDS D'ALIMENTA- TION DEVRAIENT ETRE DÉBRANCHÉS AVANT DE POURSUIVRE. 1. II y a deux endroits oü la majorité des ennuis se Lorsque l'unité...
Page 23
63123 Téléphone: (314) 577-1476 GARANTIE DE L'ACHETEUR FILTRE A AIR ELECTRONIQUE EMERSON E" lemsaN GARANTIE LIMITEE Ce filtreä air électronique White-Rodgers estgarantiecontrelesvicesde matériaux etdefabrication pouruneperiodede 12moiså compterdeIadatede son installation.II doit étre installépar un entrepreneuren chaffage ou en climatisationcompétent,en conformitéavec les directives d'installation; il doit fonctionner å...
Page 24
WHITE-RODGERS White-Rodgers Division, Emerson Electric Co. 9797 Reavis Road, St. Louis. MO 63123 (314) 577-1300...