Télécharger Imprimer la page

GAF MasterFlow PowerAtticVent EGV6HT Manuel D'instructions

Les langues disponibles

Les langues disponibles

Liens rapides

Always read and observe safety considerations
and installation instructions.
SAFETY CONSIDERATIONS & WARNINGS:
1. Use this unit only in the manner intended by
GAF. If you have any installation questions,
please contact Master Flow
Technical Services
at 1-800-211-9612.
2. For general ventilating use only. This ventilator
has an unguarded impeller. Do NOT use in
locations readily accessible to people or animals.
3. Do NOT use to exhaust hazardous material, dust,
or combustible vapors.
4. During installation, always wear appropriate
safety glasses, gloves, hard hats, restraints,
and other safety equipment to avoid injury.
Warning: Always wear durable work gloves
while handling the unit.
5. Observe all applicable building and
electrical codes.
TOOLS REQUIRED
• 3/
" or Adjustable Wrench
8
• #2 Phillips Screwdriver
• Saw (if installation requires additional
wood supports)
• Safety Eyewear
• Fall-Restraint Equipment
Figure 1a
V971382
6. Installation work and electrical wiring should be
done by a qualified person in accordance with
all building codes and the National Electrical
Code (U.S. only), including codes for fire ratings.
Contact a qualified electrician if you are not
comfortable or familiar with electrical codes
and/or installations.
7. The ventilator should be connected to a 120 volt,
60 hertz, grounded circuit only with minimum
14-gauge wiring that has at least 3 amperes of
available capacity. If you cannot confirm there is
sufficient electrical capacity on an existing circuit,
install a separate dedicated circuit. Do NOT use
an extension cord to operate.
8. Inspect for hidden utilities before cutting or
drilling. Do NOT damage electrical wiring or
other hidden utilities when cutting or drilling.
9. Make sure the fan blade is on tight and
ensure the set screw is securely tightened.
10. Ducted fans must always be vented to
the outdoors.
• Hard Hat and other Safety Equipment
• Utility Knife
• Work Gloves
• Ladder
• Claw Hammer
Figure 1b
Nut
Bolt
Shroud
Mounting Brackets
INSTRUCTIONS
For Gable Mount Models:
EGV5 & EGV6
11. Before servicing, switch power off at service panel
and lock the service-disconnect to prevent power
from being switched on accidentally.
12. FOR HOMES WITH A GAS OR OIL FURNACE
OR APPLIANCE LOCATED IN THE SAME
SPACE: The ventilator MUST be wired with a
switch or other interlocking device to prevent
the furnace and ventilator from operating at the
same time during the heating cycle. The switch
or other interlocking device MUST disconnect the
vent unit from the electrical circuit power. GAF
recommends that the switch (not included) be
installed by a qualified person in accordance
with all applicable building codes and standards.
WARNING: To Reduce The Risk Of Fire, Electric
Shock Or Injury To Persons, Do Not Use Replacement
Parts That Have Not Been Recommended By The
Manufacturer (e.g. Parts Made At Home Using
A 3D Printer)
• Pencil or Marker
• Tape Measure
• 1/2" Trade-Size Cable Clamp Connector
• Type NM Electrical Cable
• Wire Nuts
Figure 2a
We protect what matters mos t
Figure 2b
loading

Sommaire des Matières pour GAF MasterFlow PowerAtticVent EGV6HT

  • Page 1 14-gauge wiring that has at least 3 amperes of has an unguarded impeller. Do NOT use in available capacity. If you cannot confirm there is vent unit from the electrical circuit power. GAF locations readily accessible to people or animals. sufficient electrical capacity on an existing circuit, recommends that the switch (not included) be 3.
  • Page 2 1a & 1b). as shown (Figure 3). The included thermostat gaf.com/ventcalculator to ensure the minimum is adjustable from 60°F (15.5°C) to 120°F 4. Mount the Unit. Place mounting brackets so end recommended intake ventilation is installed on (48.8°C).
  • Page 3 1. Use esta unidad solo de la manera que indica a un electricista calificado si usted no está GAF. Si tiene alguna duda relativa a la instalación, 12. PARA CASAS CON HORNOS O familiarizado o no posee experiencia con comuníquese con el servicio técnico de Master...
  • Page 4 2" x 4" (50 mm x 100 mm) por medio de los de Master Flow por teléfono al 1-800-211-9612 ™ o por correo electrónico a MasterFlowTech@gaf.com. NO devuelva este ventilador al comercio minorista ni al distribuidor. Figura 3 FUENTE DE ENERGÍA...
  • Page 5 1. N'utilisez cet appareil que de la manière vous n'êtes pas à l'aise avec les codes et/ou sous tension. indiquée par GAF. Pour toute question relative installations électriques. à l’installation, veuillez communiquer avec les 12. POUR LES MAISONS AVEC UNE FOURNAISE OU 7.
  • Page 6 à l'extérieur de l'emballage boulon ainsi placé. Répétez cette opération jusqu'à n’est pas couverte. Chaque ventilateur doit avoir ou visitez le site gaf.ca/fr-ventcalculator pour vous ce que les quatre supports de montage soient son propre thermostat. Laissez un léger mou assurer que la ventilation d’arrivée d’air minimale...

Ce manuel est également adapté pour:

Masterflow poweratticvent egv5Masterflow poweratticvent egv6