ProFlow PF-MMX Instructions D'installation Et D'emploi page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PROGRAMMING INSTRUCTIONS -
CONFIGURATION PARAMETERS
Before entering the programming mode, make sure that
the appliance is in the service mode.
All configuration parameters on this appliance have
been pre-programmed in the factory, to offer optimal
performance in a wide range of applications and situations.
Nevertheless it may be necessary or desirable to change any
of these parameters, to further optimize the appliances
performance or to adapt it to the specific requirements of
the installation.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode;
any changes made will NOT be saved!
1. Press the scroll
button and hold it for 6 sec until the
display shows:
System Check
2. Within 10 sec, press the up
show:
Units:Metric
Press the up
or down
measure (Metric or US).
3. Press the scroll
button again on; the display will show:
MaintInt: 24mths
Press the up
or down
maintenance reminder function by setting the
maintenance interval, or deactivate the maintenance
reminder function.
4. Press the scroll
button again; the display will show:
ExCap:3.8°f M3/L
Press the up
or down
exchange capacity per litre of resin.
5. Press the scroll
button again; the display will show:
Age corr.:
Press the up
or down
correction factor (%/year) to compensate for capacity
loss of the resin due to aging.
ELECTRONIC CONTROL PANEL
button; the display will
button to set the units of
button to activate the
button to set the
2.0%
button to set the age
Page 11
6. Press the scroll
button again; the display will show:
Resin:XXX liters
Press the up
or down
of resin.
7. Press the scroll
button again; the display will show:
Override: 4 days
Press the up
or down
of days between regenerations.
8. Press the scroll
button again; the display will show:
Cycle 1:
XX min
Press the up
or down
of the regeneration cycle.
Press the scroll
button again to advance to the next
regeneration cycle.
Cycle 1
Backwash
Cycle 2
Brine draw/slow rinse
Cycle 3
Fast rinse/brine tank refill
9. Press the scroll
button again; the display will show:
Regen:Dlyd/Immd
Press the up
or down
regeneration mode:
 Dlyd/Immd: when the remaining capacity equals
the reserve capacity, a delayed regeneration at
the programmed time of regeneration is started;
however when the remaining capacity equals 0
before the programmed time of regeneration is
reached, an immediate regeneration is started.
 Immediate: when the remaining capacity equals
0, an immediate regeneration is started.
Note: Delayed manual regeneration is not
available when this regeneration mode is
selected.
 Delayed: when the remaining capacity equals the
reserve capacity, a delayed regeneration at the
programmed time of regeneration is started.
10. Press the scroll
button again; the display will show
(only when the regeneration mode is set to 'Delayed' or
'Dlyd/Immd'):
Regen @
Press the up
or down
regeneration.
button to set the volume
button to set the number
button to set the length
button to set the
2:00
button to set the time of