This luminaire IS Intended for Installation In accordance With the National Electric Code and Loca Regulations. To assure full
compliance with local codes and regulations, check with your local electrical Inspector before installation To prevent electrical
shock, turn off electricity at fuse box before proceeding
CAUTION. Use only reflector trim sections provided by Philips Lightolier. Use of other manufacturers reflector trims or light
engines
may void the Underwriters
A. MOUNTING
BAR
POSITION:
determine
mounting
bar position
building construction
/ lighting
mounting
bar position
needs
needed
proceed
to
B.
can be changed 90' from original position
and rotating
the
spinner
brackets
Mtg bars supplied with integral
B. FRAME—IN—KIT(for suspended
I. cut appropriate dia. hole in tile (see below * ), then orient
mtg
bars
on frame
to desired
required length then tighten mtg. bar locking screws(4
places) position fixture directly on ceiling tile then secure to
T—Bar grid
using
drill
point
screws
bars SEE FIG 3. Fixture can be additionly
wire ( provided by others)
to T—bar and building structure.
C. FRAME—IN—KIT. (for wood joist)
I) Line up bottom edge of hinged mounting bar with bottom
of joist
and fasten
in place
with frame—in—kit (depends on SKU) see FIG 4. Then swing
up frame
an extend
mtg
bars
secure to joist. Finally tight mtg bar locking screws (ref
For centering
and fixture
on
collar.
see
FIG
IA.
For tight
joist
spacing
Channel
seperated
and
shortened
. see FIG 6.
D WIRE IN:
I) open hinged J—box door then wire supply leads WHITE to
either White or Blue(depending on SKU) neutral supply lead.
Black or Brown to hot (120 or 277v) Bare copper ground
lead to supply ground using wire nuts(local
For 0—10V dimming
frames
use
for the
dimming
control.
then
close
door.
E. Ceiling (By others)
Install
plaster
board
or other
can be cut either before or after ceiling is secured to joists.
Mounting
frame
can
be used
cutout
see
below
*
F. AIRSEAL INSTALLATION(optional)
Install
a bead
of silicone
caulking
frame. Frames are tested
in accordance
2 cubic feet per minute@ 75 Pa) and comply with with WESC
&
MEC
when
installed
as
instructed.
G. DRIVER REPLACEMENT:
FIG 5
MUST be performed
by a qualified
1) Turn off power to Luminaire.
2) Remove trim assembly by pulling down on flange and
CCW for 5 & 6 in. trims (straight down on
slightly
turn
4 in trims).
3) Disconnect the connector on trim assembly.
4) Remove wing nuts that
secure internal
bring
the
door
and driver
assembly
then disconnect
wiring.
5) to reinstall driver use the reverse of step 4 above.
* CEILINGCUTOUT: 4 IN APERTURE: 4} " (111mm)
5 INAPERTURE: 51 " (140mm)
6 IN APERTURE
NOTE:
For luminaires
with dimming capatibi/ity:
Reference
dimming
compatible dimmers.
0 2016 Philips Lighting Hold-ng B.V. All rights reserved.
\oww.philips.com/ uminaires
IS:L RAE Feb-16 revD
page I of 2
INSTALLATION
INSTRUCTIONS
Read and understand these Instructions before installing luminaire.
Retain
these
instructions
Laboratories
listing and could constitute
for frame—in—kit based
application.
See below if
to
be changed.
if no change
I. Mounting bar orientation
by removing bars
see FIG.2.
nails or screws.
ceiling)
position.
Extend
mtg.
bars
provided
with
the
mtg
secured with saftey
with
screws
or nails
provided
to reach
opposite
joist
an
alignment
use alignment
notch
mounting
bar
can
be
hardware item).
the
GREY and VIOLET leads
Place all connections
in jbox
dry type
ceiling.
Hole
in ceiling
as a cutting
guide.
Ceiling
between
ceiling
opening
with ASTM E283(max
electrician.
jbox door and
through
opening
in ceiling
:
" (162 mm)
frame specification
sheets (LED-DIM) for a list of
Instruction Number I S:L
FOR
FRAME-IN-KITS
for maintenance
reference
a fire hazard
MOUNTING
BAR
is
FIG.
I
to
FRAME
MOUNTING
SCREWS
MTG.
BAR
LOCKING
SCREWS
and
FIG
6
WINGNUT
LyteCaster LED Low Profile FIK
SPINNER
BKT
ALIGNMENT
NOTCH
FIG. 2
MTG.
BAR
FOOT
AGAINST
T-BAR
FIG.
3
T-BAR
GRID
FIG
4
NTERNAL
J-BOX
DRIVER
CEILING
FIG.
5
NOTE
DRIVER
MAY
BE ON
EITHER
SIDE
OF J-BOX
PHILIPS
RAE
IA
SHOWN
DOOR
OPENING
DOOR
loading

Sommaire des Matières pour Philips LIGHTOLIER LyteCaster

  • Page 1 Retain these instructions for maintenance reference CAUTION. Use only reflector trim sections provided by Philips Lightolier. Use of other manufacturers reflector trims or light engines may void the Underwriters Laboratories listing and could constitute a fire hazard A.
  • Page 2 Conserver ces Instructions comme référence pour l'entretien MISE EN GARDE : Employer excluswement des garnitures réflecteurs fournies par Philips Lightolier. L'usage d'une garniture réflecteur ou d'un module lumiöre (moteur DEL) de tout autre fabricant peut annuler l'homologation par Underwriters Laboratories et entrainer un risque d'lncendle.