Télécharger Imprimer la page

Publicité

Liens rapides

H-10947
3M™ TC/TC-Q
GLUE GUN
OPERATING ISSUE
Low or no
adhesive flow.
Dripping nozzle.*
*Thermal expansion may cause some dripping during start-up. This is normal.
PAGE 1 OF 3
1-800-295-5510
uline.com
TROUBLESHOOTING
CAUSES
No heat.
Shutdown procedure
was not observed.
Plugged tip.
Backmelt.
Backmelt.
Contaminated
adhesive.
RECOMMENDATIONS
Check to see that the electrical 120 VAC service is turned on.
Thermal fuse in the thermostat may have blown.
Allow the glue gun to heat up for at least 30 minutes.
If the glue gun was left overnight, the tip may be plugged.
This may block adhesive flow and cause backmelt.
CAUTION! Do not force adhesive. Clear the tip with
a small nail or paperclip. Extrude the remaining
adhesive stick and add one new adhesive stick to
clear the opening.
Remove the clip and feeder from the track of the glue
gun. Push the existing adhesive stick back into the sleeve
approximately 3/4" with a new adhesive stick. Remove the
new adhesive stick before it melts and look into the black
sleeve. Look for a thin skin of adhesive around the inside of
the black sleeve. Scrape this skin toward the heat block.
CAUTION! Do not damage the black sleeve. Extrude
one adhesive stick to clear the sleeve.
To avoid backmelt, observe the start-up and shut-down
procedures. Do not force adhesive through the glue gun.
Refer to preceding paragraph on backmelt.
Keep adhesive clean and free of contamination.
Para Español, vea página 2.
Pour le français, consulter la page 3.
0625 TH-10947

Publicité

loading

Sommaire des Matières pour Uline H-10947

  • Page 1 Para Español, vea página 2. Pour le français, consulter la page 3. H-10947 1-800-295-5510 uline.com 3M™ TC/TC-Q GLUE GUN TROUBLESHOOTING OPERATING ISSUE CAUSES RECOMMENDATIONS No heat. Check to see that the electrical 120 VAC service is turned on. Thermal fuse in the thermostat may have blown.
  • Page 2 H-10947 800-295-5510 uline.mx 3M™ TC/TC-Q PISTOLA DE SILICÓN SOLUCIÓN DE PROBLEMAS PROBLEMA DE CAUSAS RECOMENDACIONES FUNCIONAMIENTO No hay calor. Verifique que el servicio eléctrico de 120 VAC esté encendido. El fusible térmico del termostato se pudo haber fundido. No siguió el Permita que la pistola de silicón se caliente por lo menos...
  • Page 3 H-10947 1 800 295-5510 uline.ca TC/TC-Q – PISTOLET À COLLE DÉPANNAGE DÉPANNAGE PROBLÈME CAUSES RECOMMANDATIONS Aucune chaleur. Vérifiez que l'alimentation électrique de 120 VCA est activée. Le fusible thermique du thermostat a peut-être sauté. La procédure d'arrêt Laissez le pistolet se réchauffer pendant au moins n'a pas été...