Part Number: REU-OPU3
Rinnai Tankless Water Heater Models:
RX/RXP199i, RX180i, RX/RXP160i, RX130i, CX/CXP199i, CX/CXP160i
RU199i/e, RU180i/e, RU160i/e, RU130i/e, RUR199i/e, RUR160i/e, RSC199i/e, RSC160i/e,
CU199i/e, CU160i/e, RE199i/e, RE180i/e
RL94i/e, RL75i/e, RUC80i, RUC90i, RUC98i, RU80e, RU90e, RU98e, RUR98i/e, C199i/e,
RUCS65i, RUCS75i, RUS65e, RUS75e
Rinnai Boiler Models:
i060C, i090C, i120C, i060S, i090S, i120S, i150S
Additional Instructions for All Models After Installation
The product model number is located on the rating plate on the side of the unit. Use the table above to identify the
appropriate page number for the instructions specific to your model number.
The REU-OPU3 is a normally Open (NO) or Normally Closed (NC) switch. This switch connects to the PC Board in the
Rinnai Tankless Water Heater or Boiler to act as:
Domestic priority control for combination domestic hot water / hydronic air handler applications.
Maintenance indicator to work in conjunction with a Building Management System (BMS) to provide system
monitoring.
Switch Rating: 24 Volts (AC or DC), 1 Amp. Systems requiring loads greater than this should be configured via an
external relay.
Before installation, please make sure all parts are located inside the product box.
Item
Description
1
S-BMS/Air Handler switch
2
Accessory Cable
3
Mounting Screw
4
Crimp Connectors
5
Alternate Cable
Philips Head Screwdriver (for removal of water heater or boiler front cover)
Double Sided Tape (for boiler models)
Smart Device such as Smartphone (for RX/RXP/CX/CXP models)
Qty
1
1
1
1
3
1
2
3
5
070 00012 37967 8
Page Number
2-3
4-5
6-7
8-9
10-14
4

Publicité

loading

Sommaire des Matières pour Rinnai REU-OPU3

  • Page 1 The REU-OPU3 is a normally Open (NO) or Normally Closed (NC) switch. This switch connects to the PC Board in the Rinnai Tankless Water Heater or Boiler to act as: •...
  • Page 2 5. Install the switch circuit board to one side of PC board, and send it a provided screw (Figure 3). Figure 3: PC Board Assembly and Switch Circuit Board OPU Installation Instructions Copyright © 2025 Rinnai America Corporation. All Rights Reserved.
  • Page 3 Bluetooth 4.0 or a newer version. Figure 4: QR code 1. Download the Rinnai Central app by scanning the QR code in Figure 4. 2. Log in the Rinnai Central app with a professional account from your LED light smart device.
  • Page 4 5. Some models require the switch to be flipped. Refer to figures 13 and 14 for the appropriate switch orientation for your model. Figure 12: Switch Circuit Board Figure 11: PCB Electrical Cover OPU Installation Instructions Copyright © 2025 Rinnai America Corporation. All Rights Reserved.
  • Page 5 0 1 A 6. Run testing. Refer to pages 10 through 12 for Air Handler, and pages 13 and 14 for S-BMS. Figure 16: Controller Display OPU Installation Instructions Copyright © 2025 Rinnai America Corporation. All Rights Reserved.
  • Page 6 DIP Switch 4 on bank one must be in the OFF position. Refer to Table 1 in the next section for more information. Figure 17 OPU Installation Instructions Copyright © 2025 Rinnai America Corporation. All Rights Reserved.
  • Page 7 *: This is applicable for only RL94i/e, RL75i/e, RUC80i, RUC90i, RUC98i, RU80e, RU90e, RU98e, RUR98i/e, RSC199i/e, RSC160i/e, CU199i/e, RUCS65i, RUCS75i, RUS65e and RUS75e. 1. Run testing. Refer to pages 10 through 12 for Air Handler, and pages 13 and 14 for S-BMS. OPU Installation Instructions Copyright © 2025 Rinnai America Corporation. All Rights Reserved.
  • Page 8 To prevent cold air from being produced, it is recommended to set Parameter 42 to “A - Continuous Run”. See the “Rinnai I-Series Boiler Installation and Operation Manual” for more information. 1. Power OFF the boiler by unplugging the power cord or turning off the circuit breaker. The controller on the boiler does not control the electrical power.
  • Page 9 -BMS. Optional LWCO Thermostat Purge Station Figure 22 PC Board Wiring for the above application example. External Pump To OPU Connection 1 Switch T/T 1 Connection Figure 23 OPU Installation Instructions Copyright © 2025 Rinnai America Corporation. All Rights Reserved.
  • Page 10 Black and White Open Wires Closed Open DPS / MIS Figure 26 Specific to Combination Space and Domestic Water Heating Applications Figure 25 Specific to error code indication OPU Installation Instructions Copyright © 2025 Rinnai America Corporation. All Rights Reserved.
  • Page 11 Figure 28: Two Stage A/C Cooling with Single Stage Heating Heating 070 00012 37967 8 Internal (Indoor) Units Figure 4: QR code Figure 29: Single Stage Heat Pump Figure 30: Two Stage Heat Pump OPU Installation Instructions Copyright © 2025 Rinnai America Corporation. All Rights Reserved.
  • Page 12 Figure 31: Single Stage Heat Pump with Auxiliary Figure 32: Two Stage Heat Pump with Auxiliary Backup Heat Backup and Emergency Heat OPU Installation Instructions Copyright © 2025 Rinnai America Corporation. All Rights Reserved.
  • Page 13 “LC” & “Set Temp” flash alternately Displayed “LC” ONLY flash “LC” ONLY flash ST Monitor Blank Closed DPS / MIS Open Error Switch Figure 34 Specific to LC code detection OPU Installation Instructions Copyright © 2025 Rinnai America Corporation. All Rights Reserved.
  • Page 14 The primary water heater controller flashes between SE and the selected set temperature. • The secondary water heater controller flashes the error code for the respective water heater. OPU Installation Instructions Copyright © 2025 Rinnai America Corporation. All Rights Reserved.
  • Page 15 à votre numéro de modèle. L’interrupteur REU-OPU3 est un interrupteur normalement ouvert (NO) ou normalement fermé (NF). Cet interrupteur relie la carte du circuit imprimé au chauffe-eau sans réservoir ou à la chaudière Rinnai pour agir comme : •...
  • Page 16 5. Installer le circuit de l’interrupteur d’un côté de la carte de circuit imprimé, et le fixer à l’aide d’une vis fournie (Figure 3). Figure 3 : Carte de circuit imprimé et carte de l’interrupteur Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 17 Bluetooth. Figure 4 : Code QR 1. Télécharger l’application Rinnai Central en numérisant le code QR à la Figure 4. 2. Se connecter à l’application Rinnai Central à l’aide d’un compte professionnel à...
  • Page 18 Figure 12 : Carte de l’interrupteur * Voir les instructions d’installation des accessoires pour obtenir plus de détails Figure 11 : Couvercle de la carte de circuit imprimé Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 19 6. Procéder à la mise à l’essai. Consulter les pages 24 à 26 pour l’appareil de traitement de l’air et les pages 27 et 28 pour le S-BMS. Figure 16 : Écran du contrôleur Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 20 L’interrupteur du boîtier DIP 4 du circuit un doit être en position ARRÊT. Consulter le tableau 1 de la section suivante pour obtenir de plus amples renseignements. Figure 17 Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 21 1. Procéder à la mise à l’essai. Consulter les pages 24 à 26 pour l’appareil de traitement de l’air et les pages 27 et 28 pour le S-BMS. Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 22 42 à « A - Continuous Run » (fonctionnement continu). Consulter le « Manuel d’installation et d’utilisation des chaudières I-Series de Rinnai » pour obtenir de plus amples renseignements. 1. Mettre hors tension la chaudière en débranchant le cordon d’alimentation ou en coupant l’électricité au niveau du disjoncteur.
  • Page 23 Station de purge Figure 22 Câblage de la carte de circuit imprimé pour l’exemple Raccord de la Vers d’application ci-dessus. pompe externe 1 l’interrupteur OPU Raccord T/T1 Figure 23 Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 24 Ouvert Fermé Ouvert DPS/MIS Figure 26 Propre aux applications de combinaison de chauffage d’espace et d’eau domestique Figure 25 Propre à une indication de code d’erreur Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 25 Appareils internes (intérieur) DÉSHUMIDIFICATEUR Figure 4 : Code QR DÉSHUMIDIFICATEUR Figure 29 : Pompe à chaleur à une phase Figure 30 : Pompe à chaleur à deux phases Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 26 Figure 31 : Pompe à chaleur à une phase avec Figure 32 : Pompe à chaleur à deux phases avec chauffage auxiliaire de secours chauffage auxiliaire de secours et d’urgence Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 27 Surveillance Affiché SEUL le voyant « LC » clignote Vide d’état Fermé DPS/MIS Ouvert Interrupteur d’erreur Figure 34 Propre à la détection du code LC Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 28 La commande principale du chauffe-eau clignote entre SE et la température de consigne sélectionnée. • La commande secondaire du chauffe-eau fait clignoter le code d’erreur pour le chauffe-eau respectif. Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 29 Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 30 Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.
  • Page 31 Instructions d’installation de l’interrupteur OPU © Rinnai America Corporation, 2025. Tous droits réservés.