R96732 R96730 R96731 R96735 R96733 R96734 Istruzioni per l’installazione della rubinetteria Instructions for the installation of the faucets Instructions pour l’installation de la robinetterie Montageanleitungen zur installation der armaturen Instrucciones para la instalacion de la griferia ИНСТРУКЦИИ ПО МОНТАЖУ СМЕСИТЕЛЬНОЙ АРМАТУРЫ...
Page 3
MAX. 115 mm EXIT EXIT PIASTRELLA MIN. 80 mm TILE INLET INLET MURO / WALL G 1/2” G 1/2” TEFLON G 3/4” G 3/4”...
Page 4
ESEMPIO INSTALLAZIONE / INSTALLATION EXAMPLE PLUG UNUSED INLETS TAPPARE ENTRATE NON UTILIZZATE Shower rain Shower blade Body jets Body jets Handshower TEFLON G 3/4”...
Page 5
R96734 TEFLON G 3/4” G 3/4” 2 VIE 2 WAYS R96735 3 VIE TEFLON 3 WAYS G 3/4” G 3/4”...
Page 9
NON INCLUSE FISSAGGIO CARTONGESSO NOT INCLUDED DRYWALL INSTALLATION PAG 7 PER MISURA FORO FOR HOLE DIMENSION...
Page 10
SEGUIRE INSTALLAZIONE DA PAG.7 FOLLOW INSTALLATION FROM PAG.7 SEGUIRE INSTALLAZIONE DA PAG.7 SEGUIRE INSTALLAZIONE DA PAG.7 FOLLOW INSTALLATION FROM PAG.7 FOLLOW INSTALLATION FROM PAG.7...
Pressure difference between hot /cold water: 1 bar max. Maximum temperature: 80°C Recommended temperat.: 60-65°C Zucchetti taps can be used with electric storage water heathers and instant gas types, centralised system, combi wall-mounted gas boilers and district heating systems. Before connecting the taps we recommend draining the system thoroughly. Should the water pres- sure be higher than 5 bar, a pressure reducer should be fitted upstream of the supply pipes.