In Cold Climates; Exposure To Strong Sunlight - Johnson Aurum R290 M Serie Manuel D'installation, D'utilisation Et D'entretien

Montrer les pouces Voir aussi pour AURUM R290 M Serie:
Table des Matières
Les langues disponibles

Les langues disponibles

The downpipe must go into a sufficiently large gravel
bed so that the condensate can trickle away freely.
NOTE
To prevent the condensate from freezing,
self-regulating heating cable(field supply) must
be threaded into the downpipe so that the
condensate can discharge via the downpipe.
Draining condensate through a pump sump/
soakaway
e
a - Outdoor unit
b - Concrete strip foundations
c – Foundation (See 5.3.1 Installation on a ground)
d - Drain pipe(at least DN 40)
e - Pump sump/soakaway
Sewer
e
a - Outdoor unit
b - Concrete strip foundations
c – Foundation (See 5.3.1 Installation on a ground)
d - Drain pipe (at least DN 40)
e - Sewer
f - Stench trap in an area free from frosting risks
Installation on a solid ground
Guide the condensation pipe to a sewer, pump sump or
soakaway.
a
c
b
d
a
c
b
d
f
31
The drain plug in the accessory pack cannot bend to
another direction. For this, use a hose to guide the
condensate into a sewer, pump sump or soakaway
through a gully, balcony run-off or roof run-off.
Open gullies within the safety zone do not pose any
safety risk.
Installation on a flat roof
Refer to Installation on a solid ground.
NOTE
For all installation types, ensure that any
condensate that accumulates is discharged into a
frost-free area.
To prevent the condensate from freezing,
self-regulating heating cable(field supply) can be
threaded
into
the
downpipe
condensate can discharge via the downpipe.

5.5 In cold climates

It is recommended that the unit be placed with the rear
side against the wall.
Install a lateral canopy on top of the unit to prevent lateral
snowfall in extreme weather conditions.
Install a high pedestal or wall mount the unit to keep a
proper clearance (at least 100 mm) between the unit and
snow.
① Canopy or alike
② Pedestal in case of installation on a ground
If there is a risk of snow slip from the roof,
protective roof or cover must be erected to protect the
heat pump, pipes and wiring.

5.6 Exposure to Strong Sunlight

Long time of exposure of the ambient temperature
sensor of the unit to sunlight might impact the sensor
negatively, and cause undesirable impacts on the unit.
Shade the unit with a canopy or alike.
so
that
the
a
Table des Matières
loading

Table des Matières