Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

1U03 1781
Model: ECW-300/360
SAFETY INSTRUCTIONS
Before installation and operation, read these instructions carefully
and use this product only in the manner described by the
manufacturer in the operation manual.
The instruction shown below are used to alert you to potential
personal injury and property damage hazards.
There are three hazard classifications based on potentially
dangerous situations.
Obey all safety instructions that show these symbols to avoid
possible injury, death and property damage.
WARNING:
WARNING indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
CAUTION:
CAUTION indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
CAUTION:
CAUTION used without the safety
alert symbol indicates a potentially
hazardous situation which, if not
avoided, may result in property
damage.
NOTE: The safety instructions are explained with the following
pictographic symbols.
means prohibition. It indicates actions, if any,
that mustn't be done.
means forcible execution. It indicates actions, if
any, that must be done.
WARNING
1. TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
b) Before servicing or cleaning the unit, switch power
off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.
2. To reduce the risk of fire or electric shock, do not
use this product with any solid-state speed control
device.
3. TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Installation work and electrical wiring must be
done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-
rated construction.
1. Preparation
WARNING:
• Ensure that the metal duct does not touch other metal housing
materials, otherwise fire or electric shock could result.
Round duct
1
This range hood is designed to
(For vertical discharge)
discharge upward. For vertical
(ECW-300=6"/ECW-360=7")
discharge, run duct work
between the hood location and
roof cap location.
To get the best result, use a
minimum number of transitions
Soffit
and elbows.
Be sure to attach a roof cap to
avoid rain from entering into the
exhaust duct.
Range hood
CAUTION:
• Install the range hood unit on a wall where durable
enough to support its weight. Otherwise, it may be
detached and fall down.
Reinforce the wall with some wood panel if necessary.
2
Referring to the figure right,
arrange the end of 6" or 7" round
A
duct just above the exhaust port of
the range hood unit.
Range hood
A
B
Duct
ECW-300
5-5/16" (135)
1" (25)
30~50
ECW-360
5-7/8" (150) 3-5/16" (83.7)
mm
Unit : inch (mm)
3
Referring to "DIMENSIONS" above, insert
5mm
2 supplied wood screws into the mounting
wall for the left and right keyholes of the
hanger. Allow about 5mm space between
the wall and screw-heads for hanging.
2. Range Hood Mounting
CAUTION:
• Wear working gloves to avoid injury.
1
(1) Installing hanger
Put the supplied hanger
on the hood top, and fix it
using screws attached on
the top plate.
(2) Installing exhaust port
Detach the tape on the
ECW-300
exhaust port, then with
Tape
paying attention to the
shutter opening direction,
fix it using screws
attached on the top plate.
Shutter opening
direction
Exhaust port
INSTALLATION MANUAL
b) Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer's
guidelines and safety standards such as those
published by the National Fire Protection
Association (NFPA), and The American Society
for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
c) When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
d) Ducted fan must always be vented to outdoors.
4. TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
5. This unit must be grounded.
6. Check that the hood is correctly installed, since
incorrect installation could result in the range hood
becoming detached and falling off.
7. Connect only to an AC120 Volt power source or
the range hood could result in fire, electric shock,
and damage.
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive material and
vapors.
2. To reduce the risk of fire and to properly exhaust
air, be sure to duct air outside. Do not vent exhaust
air into spaces within walls, ceilings or into attics,
crawl spaces or garages.
3. Read specification label on this product for further
information and requirements.
4. Use only for the purpose of kitchen ventilation.
5. Do not install this range hood in the bathroom or
in other wet rooms since electrical shock and
damage may result.
6. Fasten the filter and other parts securely. Incorrect
attachment may result in personal injury or
property damage.
2
Detach the rectifier
baffle panel by
loosening 2 fixing
screws, sliding it to
dislocate the keyholes
from the screws, and
3
disengaging it from
Filter
the catches.
3
Detach the filters by
turning the fixing
Roof cap
knobs counter-
clockwise, and
disengaging them
from the supporting
2
groove.
Rectifier baffle panel
4
With inserting the exhaust
port into the duct, hook
both the left and right
keyholes of the hanger on
the screws provided in
"Preparation" step 3.
B
Tighten screws
to fix
Center line
5
Tighten both the left and
right screws, and fix the
range hood securely
adding 4 more supplied
washer head wood
screws to the holes on
the hanger and back of
the range hood.
6
Make the duct joint secure
and air-tight using non-
flammable tape such as duct
tape, etc. (Not supplied)
Non-flammable tape
3. Connecting Power Supply Wires
WARNING:
• Electrical wiring should be done by a qualified person(s) in accordance
with all applicable codes and standards, including fire-rated
construction. An unqualified person doing the work could result in
fire, electric shock or injury.
Hanger
• This range hood uses 120V AC. Do not connect to other voltage since
fire, electric shock or damage could result.
ECW-360
1
Remove the nut from the conduit
connector at the end of power wiring.
WARNING:
Be sure to switch OFF the power
at service panel before wiring.
Range Hood
NAMES OF PARTS
Duct Cover
Control Switches
Fan
Filter
Rectifier Baffle Panel
DIMENSIONS
ECW-300
1"(25)
3-3/4"(95)
11"(280)
13/16"(20)
13/16"(20)
30"(761)
24"(610)
ECW-360
2-5/8"(66)
5-7/8"(150)
17"(432)
13/16"(20)
13/16"(20)
36"(913)
24"(610)
INSTALLATION
2
Loosen 2 screws
Remove each screw fixing the
to remove the filter
wire cover and detach it.
Loosen 2 screws
to remove the
3
Connect the
rectifier baffle panel
conduit through
the connecting
hole of the
enclosure using
the nut previously
removed.
Hanger
4
Connect wires tightly and securely
using wire connectors
(not supplied).
Connect the electrical
wires as follows:
• Black to Black
• White to White
• Green to Green
5
Replace the wire cover with the
screw(s) removed previously.
Make sure that all wires are
connected properly and
enclosed inside of the wiring
compartment.
4. Attaching Duct Cover
1
Referring to "DIMENSIONS" and
"RANGE HOOD LOCATION" above,
calculate the duct cover height
necessary to cover between the
range hood top and ceiling.
Conduit
(Not supplied)
2
For height adjustment, loosen 3
wing-bolts of the duct cover and pull
the inside slide cover up to the height
calculated.
3
Nut
Tighten 3 wing-bolts securely to fix
(Not supplied)
the inside slide cover.
ECW-300
Pilot Lamp
Lamp Switch
OFF Switch
High Switch
Low Switch
Medium Switch
Hanger
ECW-360
Unit: inch (mm)
• Screw
M5.1×45
Four (4) pcs.
• Wood Screw
M4.5×45
Two (2) pcs.
• Screw M4×10
Two (2) pcs.
9-1/16"(230)
18"(457)
4-∅3/8"(∅9)
(Hood Mounting Hole)
RANGE HOOD LOCATION
1
The range hood must be installed just
above the cooktop.
2
The minimum distance from the cooking
surface to the bottom of the range hood
must be 24".
3
The total weight of the range hood units
are as follows;
4
Power requirements are:
ECW-300: AC120 V, 60 Hz, 2.5 Amp
ECW-360: AC120 V, 60 Hz, 3.0 Amp
CAUTION:
• Check that the hood is correctly installed, since incorrect installation could
result in the detachment of the range hood and the unit could fall down.
15-1/16"(382)
18"(457)
• To protect hands from injury, wear working gloves when installing the range
4-∅3/8"(∅9)
(Hood Mounting Hole)
hood.
4
Set the duct cover on the range hood unit, and fix it to the range
hood unit using 2 screws supplied.
ECW-300
ECW-360
Screw
Screw
Wire cover
Wire cover
Conduit
Nut
1
Assembly
Attach the filters and rectifier baffle panel referring to the steps
described in "2. Range Hood Mounting".
Two 50 W halogen light bulbs (not supplied)
can be mounted in this range hood.
Prior to function check, install light bulbs
Wire connector
(PAR20 bulb, in the base diameter
26 mm: medium base), rated
120 V - 50 W or below.
ECW-300
Turn the lamps clockwise
to install them.
Hook
2
Check
ECW-360
(1) Turn on the power to the range hood.
Wire cover
(2) Make sure that the switchs and light operate correctly.
(3) Make sure that the range hood functions properly and it has
Screw
Wire cover
Screw
6. Explanation to the End User
(1) Referring to the Operation Manual, explain the operation of this
range hood to the end user.
Wing-bolt
(2) The Installation Manual and Operation Manual should be given to
the end user.
2
Loosen
3
Fix
CIRCUIT DIAGRAM
Lamp Switch
Fan Switch
Motor
Connector
Pilot Lamp
Connector
Black
White
Grey
Yellow
Black
Lamp 50W
Yellow
Yellow
White
White
Black
Black
Connector
Connector
Connector
White
White
Black
Black
Connector
Lamp 50W
Black
Capacitor
Grey
Grey
120V
60Hz
White
Purple
Purple
Green
Lamp Switch
Fan Switch
Connector
Pilot Lamp
Connector
Black
White
Grey
Yellow
Black
Lamp 50W
Yellow
Yellow
Motor
White
White
Black
Black
Connector
Connector
Connector
White
White
Black
Black
White
Lamp 50W
Connector
120V
Black
Capacitor
60Hz
Grey
Grey
Green
Purple
Purple
ACCESSORIES
• Hanger
One (1) pc./ea.
(For ECW-300)
(For ECW-360)
• Exhaust Port
One (1) pc./ea.
24"(minimum)
ECW-300 50.7 lbs. (23kg)
ECW-360 70.5 lbs. (32kg)
Cook top
Hanger
Duct cover
Hanger
Duct cover
5. Assembly and Check
Filter
Rectifier baffle panel
Bulb
(Not supplied)
Refer to page 4 of the Operation Manual.
no abnormal noises and/or vibration.
Push to turn ON

Publicité

loading

Sommaire des Matières pour Fujioh ECW-300

  • Page 1 Cook top damage may result. device. Power requirements are: ECW-300: AC120 V, 60 Hz, 2.5 Amp 3. TO REDUCE THE RISK OF FIRE, ELECTRIC ECW-360: AC120 V, 60 Hz, 3.0 Amp SHOCK, OR INJURY TO PERSONS, OBSERVE 6. Fasten the filter and other parts securely. Incorrect 13/16"(20)
  • Page 2 Le poids total des hottes d’aspiration est 17"(432) d’électrocution n’utilisez pas cet appareil avec un comme suit; Surface de ECW-300 50.7 lbs. (23kg) dispositif de commande de vitesse à semi- cuisson ECW-360 70.5 lbs. (32kg) conducteurs. 5. N’installez pas la hotte d’aspiration dans la salle de bains ou dans d’autres pièces humides car des...

Ce manuel est également adapté pour:

Ecw-360