SAFETY INSTRUCTIONS
KEEP THESE INSTRUCTIONS
This fixture is intended for installation in accordance with the National Electric Code (NEC) and Local code
specifications. Failure to adhere to these codes and instructions may result in serious injury and/or property
damage and will void the warranty.
1) WARNING: This fixture is not to be installed within 10 feet (3M) of a pool, spa or fountain.
2) According to the requirements of the National Electric Code (NEC), direct burial rated wire is to be buried a
minimum of 6" [152mm] beneath the surface of the ground.
NOTE: If additional Direct Burial wire is needed, contact your local Kichler
• 8 GA wire can be purchased in length of 250' (76 M),15503-BK.
• 10 GA wire can be purchased in length of 250' (76 M),15504-BK.
• 12 GA wire can be purchased in lengths of 100' (30 M),15501-BK; 250' (76 M), 15502-BK; 500' (152M),
15505-BK; and 1000' (304 M), 15506-BK.
3) Wiring connections must be made with approved/listed wire connection device(s) suitable for the application. Do
not exceed manufacturers' wiring combination specifications for size and quantity of conductors.
WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW VOLTAGE), CARE SHOULD BE
TAKEN TO KEEP CLEAR OF POTENTIALLY COMBUSTIBLE MATERIALS.
WHEN MAINTAINING THE FIXTURES, BE SURE TO REMOVE LEAVES, PINE NEEDLES, GRASS CLIPPINGS,
MULCH, OR ANY DEBRIS THAT HAS ACCUMULATED ON THE LIGHT BULB, LENS, OR BODY OF THE FIXTURE.
ASSEMBLY AND INSTALLATION
1) Determine desired location for mounting fixture.
2) At desired location, hammer stake into ground. To avoid damage to stake, place a board on top of
stake while hammering. If ground is hard and stake is difficult to install, make a crosscut in ground
using a flat shovel.
3) Clear away area in ground at wireway slot in top of stake.
4) Lay 12V cable into wireway slot and screw fixture into stake. Aim fixture in desired direction and
secure by tightening locknut. If necessary, use wrench or pliers for final tightening of nut.
5) Adjust angle of fixture by loosening hex head screw.
6) TURN OFF POWER.
7) Make wire connections using supplied wire connectors following instructions included, or using
other approved wiring connection method (not supplied).
TO CHANGE LIGHT OUTPUT SETTING:
NOTE: Fixure switches up in terms of lumen settings; it starts at low (500 lumens). If this level is
desired, no adjustment is needed.
Locate the dimple at the side of the fixture. (This is called a lumen adjustment switch locator)
Hold magnet on lumen adjustment switch locator for 1.5 seconds to begin programming mode.
Remove magnet.
Fixture will blink continuously 4x's at full brightness level and go dark for 2 seconds and then will
illuminate at original factory setting.
To switch lumen settings, magnet must be reapplied to lumen adjustment switch locator for 1.5
seconds and magnet must be removed for 1 second between switching.
NOTE: fixture blinks 1x for the lowest lumen setting; 2x's for the middle lumen setting, and 3x's for
the highest lumen setting.
Once the fixture is set and magnet removed, it stays in programming mode for 2 minutes.
After 2 minutes, the memory is set.
To change the output brightenss, return to programming mode by holding magnet on magnetic
locator for 1.5 seconds.
NOTE: Fixture reverts back to original factory setting when put back into programming mode.
NOTE: Once the desired setting is set, mark the level (1, 2, or 3) with a marker on fixture under the
cowl.
Wire   G auge/Power/Length   C hart
Wire   G auge/Length   ( ft/m)   p er   r un
WATTS   ( VA)
10
0   -­‐   2 0
1860/567
40
930/283
60
620/189
80
470/143
100
370/113
                                                                C onsult   T echnical   S upport
>100
Fixture Load Chart
Lumen Level
3
2
1
1
NOTE: When sizing your transformer please use the highest VA you expect
to use depending on desired lumen level per fixture to prevent potentially
overloading the transformer.
Best practice is to use VA/wattage buffer of 30% when sizing a transformer
to account for fixture lumen adjustments. (ie. 210 VA on 300V transformer.)
Date Issued: 12/06/17
IMPORTANT! PLEASE READ
READ THIS FIRST
landscape distributor.
®
CAUTION
12
14
16
1150/351
730/223
450/137
580/177
370/113
230/70
390/119
240/73
150/46
290/88
180/55
110/34
230/70
140/43
90/27
VA (AC Power
WATTS (DC Power
Supplies)
Supplies)
23
18.5
16
12.5
9
9
7
7
For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page
Pour de plus amples informations sur la garantie, veuillez visiter : http://www.landscapelighting.com/portal/warranty_page
LUMEN ADJUSTMENT
SWITCH LOCATOR
PROGRAMMING MODE
Lumen Level Table (For 2700K/3000K)
Single Flood LED
16022
*500 Lm
* DENOTES FACTORY SETTING
LUMEN ADJUSTMENT
SWITCHING
SWITCH LOCATOR
MAGNET
Customer Service: 866-558-5706
Technical Support: 844-452-4537
Hrs: M-F 9am to 5pm EST
FIXTURE
HEX HEAD SCREW TO
ADJUST ANGLE OF FIXTURE
LOCKNUT
STAKE
WIRE LEADS
SWITCHING
MAGNET
Gen 3 Lumen Table for IS -
Level 1
Level 2
Level 3
700 Lm
900 Lm
PROGRAMMING
IS-16022-CB
ORIGINAL
MODE
LEVEL 1
LEVEL 2
LEVEL 3

Publicité

loading

Sommaire des Matières pour Kichler VLO 2700K

  • Page 1 3) Wiring connections must be made with approved/listed wire connection device(s) suitable for the application. Do not exceed manufacturers’ wiring combination specifications for size and quantity of conductors. CAUTION WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW VOLTAGE), CARE SHOULD BE HEX HEAD SCREW TO ADJUST ANGLE OF FIXTURE TAKEN TO KEEP CLEAR OF POTENTIALLY COMBUSTIBLE MATERIALS.
  • Page 2 à l’application. Ne pas dépasser les spécifications de câblage du fabricant concernant le calibre et la quantité des conducteurs. ATTENTION LORS DE L’INSATLLATION D’ÉCLAIRAGE DE PAYASGE KICHLER®, PRENDRE SOIN DE CHOISIR UN SITE À L’ÉCART DE MATÉRIAUX POTENTIELLEMENT INFLAMMABLES. LORS DE L’ENTRETIEN DES LUMINAIRES, PRENDRE SOIN D’ENLEVER FEUILLES, AIGUILLES DE PIN, TONTE CONTRE-ÉCROU...

Ce manuel est également adapté pour:

Vlo 3000k16022azt2716022bkt2716022azt3016022bkt30