1. SPECIFICATIONS
CX-92S-06
600 lbs. x2 (Factory Tested) **
Static Strength
500 lbs. x2 (UL Verified)
50 ft-lb
Dynamic Strength
12/24V DC
Voltage Input
Current Draw
480mA/240mA x 2
19-3/4"W x 2"H x 1-1/8"D
Dimensions
(500mm x 50mm x 29mm)
(Body)
2 x 7-5/32"W x 1-3/4"H x 15/32"D
Dimensions
2 x (182mm x 44mm x 12mm)
(Armature Plate)
250,000
Endurance
2. BASIC INSTALLATION CONCEPT & ACCESSORIES (FIGURE 1)
General Installation
Door
Frame
EM
Lock
Door
Out Swing
LS Bracket For Out-Swing Door
Fixing
Door Frame
Screw
EM
Lock
Door
Out-Swing
T Handle Allen Key
(Not Included)
Cable Wire
x 4
Armature Screw
Armature
Plate
Electromagnet
Anti-Tamper Nut x4
Rubber
Washer
Allen Wrench
Guide Pin x2
(Not Included)
CX-92S-12
1200 lbs. x2 (Factory Tested) **
1000 lbs. x2 (UL Verified)
70 ft-lb
12/24V DC
420mA/210mA x 2
21"W x 2-5/8"H x 1-9/16"D
(532mm x 67mm x 39mm)
2 x 7-9/32"W x 2-13/32"H x 5/8"D
2 x (185mm x 61mm x 16.5mm)
250,000
Armature Screw
Armature Plate
PCB Cover
Guide Pin x2
Cover Screw
Anti Residual Magnetism Button
Sexnut Bolt
Metal Washer
1200 lb.
600 lb.
Performance Levels
- Destructive Attack = Level I
- Line Security = Level I
- Standby Power = Level I
- Endurance = Level IV
U1 Bracket For Glass Door
Mounting Plate
Glass Door
Self-tapping Screw x10
Cover Screw
Out-Swing
Electromagnet
In-Swing Door With Cover
Anti Residual
Door
Magnetism
Frame
Button
Rubber
Sexnut Bolt
Washer
Metal Washer
LZ Bracket For In-Swing Door
Self-tapping Screw
UL 1034 / UL 294
Standard for
Burglary-Resistant
Electric Locking
Mechanisms
ULC S533-15
Standard for
Access and Egress
Door Frame
EM
Lock
LZ Bracket For
CSK M8 x16
EM
Lock
M4 Set Screw
Door
In-Swing
Door
Frame
EM
Lock
P/H MC Screw
Door
M4 x 8
In-Swing
Page 1 of 2

Publicité

loading

Sommaire des Matières pour CAMDEN CX-92S

  • Page 1 Access Control Accessory E l ec t r if i e d Lo ck s , R e l ay s a n d Time rs UL 1034 / UL 294 CX-92S 600lb. & 1200lb. Standard for 1200 lb. Burglary-Resistant...
  • Page 2 CX-92S 600lb. & 1200lb. Magnetic Locks INSTA L L AT I O N I NST RU CTI ONS 3. INSTALLATION 4. TROUBLE SHOOTING 1. Drill the armature plate holes in the door using the sticker template provided. 1. Door not locked: - Incorrect wiring or no power from power supply .
  • Page 3 S er r ur e s él e ct r i q u e s , r e l a is e t minu te rie s UL 1034 / UL 294 CX-92S 600lb. & 1200lb. Standard for 1200 lb.
  • Page 4 CX-92S 600lb. & 1200lb. Magnetic Locks INSTA L L AT I O N I NST RU CTI ONS 3. INSTALLATION 4. DÉPANNAGE 1. Percer les trous de la plaque d’armature dans la porte à 1. La porte ne verrouille pas: l’aide du gabarit autocollant fourni.

Ce manuel est également adapté pour:

Cx-92s-06Cx-92s-12