Liens rapides

READ INSTRUCTIONS AND REVIEW ALL DIAGRAMS BEFORE INSTALLING THE FIXTURE.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CAUTION:
Risk of electrical shock. Make sure the power supply is OFF before installing or maintaining the fixture.
Never perform maintenance or cleaning while the fixture is powered.
Disconnect the power and ensure the fixture is cool before maintaining.
INTENDED APPLICATION:
Input Voltage: 120-277VAC (120-347VAC optional), 50/60Hz, CHECK THE PRODUCT LABEL RATINGS
BEFORE ATTEMPTING INSTALLATION.
Mounting Height: >4ft (1.2 meter) from the ground.
Designed to operate in temperatures ranging from -40°F to 113°F (-40°C to 45°C).
GENERAL:
This product MUST be installed or serviced in accordance with the applicable installation code by a qualified licensed electrician.
Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety.
DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should be damaged during transit. Throughly
inspect the fixture for any freight damage; freight damage should be reported to the delivery carrier and EEL.
All wiring connections should be capped with UL/CSA LISTED wire connectors.
Keep combustible and other materials that can burn, away from lamp/lens
Do not mount or support these fixtures in a manner that can cut the outer jacket or the insulation of the wires.
Some components inside the fixture may not be serviceable. In case you require service, stop using the unit immediately and contact EEL for
.
assistance
Note: For Wet location compliance, fixture must be properly sealed. Apply weatherproof silicone sealant (not provided) all along the
top and sides of the fixture to ensure the fixture is sealed tightly against the surface. DO NOT seal the bottom of the fixture. Apply
weatherproof silicone sealant on wiring access holes and mounting screw head. Failure to do such shall render the warranty null
and void.
ASSEMBLY AND INSTALLATION:
1. Open the fixture by unscrewing off two
bolts. Disconnect the quick connector
(between LED module and LED driver)
inside the fixture and take off front
housing.
Threaded cap
5. Remove the desired threaded cap
on the fixture.
7. Fix the rear housing on the wall with
self-tapping screws. Seal all wiring
access holes and mounting screw
heads with weatherproof silicone
sealant (not provided).
Installation Instructions for Semi Cut-off Wall Pack
WP 3254 / WP 3354 / WP 3554
2. Drill holes on the wall
according to the three
standoffs on the housing.
6. If surface mount, run wires through the back of the rear housing (1). If conduit mount, feed the
conduit into the rear housing through side knockout (2).
8. Connect the wires according to the
wiring diagram.
Energy Efficient Lighting Limited | www.eelighting.ca | Tel: 1-855-415-8878
3. Use a hammer to
hammer the nylon
expansion anchors into the
drilled holes on the wall.
(1)
9.
Attach the front housing back on the rear
housing. Reconnect the quick connector. Re-mount
fixture using phillips head screws that were
removed in the mounting step. Make sure all
gaskets and holes are properly sealed and
tightened firmly.
Included For Installation
4pcs - Self tapping screws with O-rings
4pcs - Anchors
3pcs - Approved wire nuts
2pcs - Hole plugs
1pc - Liquid tight connector
4. Knock out or drill appropriate holes on
the rear housing. Level the fixture with
the level ruler and secure it to the
wall/junction box. Refer to "Product
information bulletin".
(2)
R200908-1500

Publicité

loading

Sommaire des Matières pour EE Lighting WP3254

  • Page 1 Installation Instructions for Semi Cut-off Wall Pack WP 3254 / WP 3354 / WP 3554 Included For Installation READ INSTRUCTIONS AND REVIEW ALL DIAGRAMS BEFORE INSTALLING THE FIXTURE. KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. 4pcs - Self tapping screws with O-rings CAUTION: Risk of electrical shock.
  • Page 2 Installation Instructions for Semi Cut-off Wall Pack WP 3254 / WP 3354 / WP 3554 READ INSTRUCTIONS AND REVIEW ALL DIAGRAMS BEFORE INSTALLING THE FIXTURE. KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. WIRING DIAGRAM Black (line) White (Neutral) LED DRIVER Green / Yellow (GRD) Lead wire 12.
  • Page 3 Instructions d'installation pour l'ensemble mural à semi-coupure complète WP 3254 / WP 3354 / WP 3554 Included For Installation LIRE ATTENTIVEMENT AVANT D'INSTALLER LE LUMINAIRE. CONSERVER CES INSTRUCTIONS À DES FINS DE RÉFÉRENCES. 4 pièces - Vis autotaraudeuses AVERTISSEMENT: avec joints toriques RISQUE DE DÉCHARGE ÉLECTRIQUE S'assurer que l'alimentation principale est HORS CIRCUIT avant 4 pièces - Ancrages d'installer ou d'entretenir le luminaire.
  • Page 4 Instructions d'installation pour l'ensemble mural à semi-coupure complète WP 3254 / WP 3354 / WP 3554 LIRE ATTENTIVEMENT AVANT D'INSTALLER LE LUMINAIRE. CONSERVER CES INSTRUCTIONS À DES FINS DE RÉFÉRENCES. Diagramme général de câblage Noir (ligne) Blanc (neutre) CIRCUIT ÉLECTRONIQUE Vert / jaune POUR DEL (mise à...

Ce manuel est également adapté pour:

Wp3354Wp3554