Télécharger Imprimer la page
Honeywell Home RPLS540A Guide De L'utilisateur
Honeywell Home RPLS540A Guide De L'utilisateur

Honeywell Home RPLS540A Guide De L'utilisateur

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

RPLS540A/RPLS541A
Applications
The RPLS540A/RPLS541A programmable wall switch can be used in a single-switch or 3-way installation with the following types of
lighting:
• Incandescent
• Halogen
• Low-voltage halogen with transformer
The RPLS540A/RPLS541A switch cannot be used with a load of less than 40 W or more than 500 W.
Installation
 
ut power at the circuit breaker to avoid electric shock.
Remove the existing switch. (For a 3-way installation, identify and label the wire connected to the "common" screw.)
Install the new switch.
Apply power at the circuit breaker.
WARNING: Disconnect power to the switch when replacing a light bulb (see section 4).
SINGLE-SWITCH INSTALLATION
black
120
VAC
white
black
120
VAC
white
white
black
Connect the LINE and 3 WAY wires to the line (120 V) wire and LOAD wire to the load. Connect the GND wire to a ground screw inside
the electrical box.
EXISTING 3-WAY INSTALLATION
black
black
120
VAC
jumper
white
white
black
three-way
switch
Connect the LOAD wire on the RPLS540A/RPLS541A to the "common" wire, which you identified when removing the old switch.
Connect the GND wire to a ground screw inside the electrical box. Connect the LINE and 3-WAY wires to the two remaining wires. At
the other 3-way switch, connect the jumper wire between the "common" screw and the screw where the LINE wire of the RPLS540A/
RPLS541A is connected.
NEW 3-WAY INSTALLATION
black
black
120
VAC
white
white
RPLS540A/RPLS541A
• Fluorescent
black
yellow (3-WAY)
white
black (LINE)
green (GND)
black (LOAD)
yellow (3-WAY)
black (LINE)
green (GND)
black (LOAD)
black (LINE)
green (GND)
black (LOAD)
yellow (3-WAY)
white
red
black
black (LINE)
green (GND)
black (LOAD)
yellow (3 WAY)
white
1.
Quick Start-up
Set the time and date before using the switch for the first time.
The RPLS540A/RPLS541A will turn the lights on at sunset and turn them off at 11:00 pm by default. If these settings are
appropriate for you, you only need to set the time and date (see shaded zone in the menu flowchart sheet). If the switch's sunset time
does not correspond to the actual sunset time, see sections 5.3.3 and 5.3.4.
2.
Operation
Indicates the mode of operation
(see Section 5.1)
Indicates the time and day
Indicates the current program
Indicates the load on/off state
Briefly press this button to turn the lights
on or off. See "Temporary Override" in
Section 5.1.4.
Press for 3 seconds to enter the setup
menus.
Before replacing a light bulb, pull out to disconnect power to the switch. This prevents, while the bulb is out, any possible
short circuit which will damage the switch. Push back in after the light bulb is replaced.
Setup Menus
Press the main button for 3 seconds to enter the setup menus. Refer to the menu flowchart
sheet on how to navigate the menus.
(3 sec.)
5.1
Mode Menu
Use the Mode menu to select one of the three modes of operation (see sections 5.1.1 to 5.1.3).
5.1.1 Manual Mode
In Manual mode, the RPLS540A/RPLS541A operates like a regular switch. To turn the lights on or off, briefly
press the main button. The
5.1.2 Automatic Mode
In Automatic mode, the RPLS540A/RPLS541A turns the lights on or off according to the set programs (see
Section 5.4). The
icon as well as the current program number are displayed.
5.1.3 Random Mode
In Random mode, the RPLS540A/RPLS541A has no specific times to turn the lights on or off. This mode is
designed to give the impression the house is occupied during your absence. It is similar to the Automatic mode
except there is no fixed program. The programs are automatically set to different times by the RPLS540A/
RPLS541A every day. The
The first "On" program occurs at sunset. Each "On" program lasts between 1 hour and 1 hour and 30 minutes;
each "Off" program lasts between 15 and 30 minutes. The last "Off" program occurs between 10:30 pm and
midnight.
5.1.4 Temporary Override
When the RPLS540A/RPLS541A is in Automatic or Random mode, you can press the main button at any time to override the default
single-pole
state for the current program. The lights will turn off if they are on and vice versa. The icon (On or Off) of the new state flashes to
switch
indicate that the state is temporary. The new state is maintained until you press the main button again or till the next "On" or "Off"
program.
7-day Solar Programmable Wall Switch
The
icon indicates the current program has been
activated at sunset.
The
icon indicates the current program has
been activated at sunrise.
Press this button to display today's sunrise time.
Press this button to display today's sunset time.
The LED illuminates when the load state is on.
M38932
Safety switch
icon appears when the switch is in Manual mode.
icon appears when the switch is in Random mode.
User guide
3.
4.
5.
1/8

Publicité

loading

Sommaire des Matières pour Honeywell Home RPLS540A

  • Page 1 Set the time and date before using the switch for the first time. lighting: The RPLS540A/RPLS541A will turn the lights on at sunset and turn them off at 11:00 pm by default. If these settings are • Incandescent • Halogen •...
  • Page 2 — P02 Off to None — When automatic daylight savings time changeover is on (DLS On), the RPLS540A/ If the product is defective, P07 On P07 Off RPLS541A changes to daylight savings time (summer time) at 2:00 am on the second...
  • Page 3 « GND » à la vis de mise à la terre dans la boite électrique. Relier les fils « LINE » et « 3-WAY » aux deux fils restants. Pour l’autre interrupteur à 3 voies, relier le fil de raccord (fourni) entre la borne « commun » et la borne sur laquelle le fil « LINE » du RPLS540A/ En mode Aléatoire, le RPLS540A/RPLS541A n’a pas de moment précis pour allumer ou éteindre les lumières.
  • Page 4 Précision du tableau solaire : +/- 11 min. (latitudes inférieures à ±60°) Exemple 1 : Chaque jour, les lumières s’allument au coucher du soleil et s’éteignent à Certification : UL (c UL us) Quand le passage automatique à l’heure avancée est activé (DLS On), le RPLS540A/  23h (réglages par défaut).
  • Page 5 Ajustar la hora y la fecha antes de utilizar el interruptor por primera vez. tres vías con los siguientes tipos de iluminación: El RPLS540A/RPLS541A encenderá las luces a la puesta de sol y las apagará a las 23 horas por defecto. Si este horario no fuera • Incandescente •...
  • Page 6 Ejemplo 1: cada día, las luces se encienden con la puesta de sol y se apagan a las Garantía 23:00 (ajustes por defecto). Cuando se activa el cambio a la hora avanzada (DLS On), el RPLS540A/RPLS541A pasa a la hora avanzada o hora de verano a 2:00 el segundo domingo de marzo y a la Programa Días...
  • Page 7 RPLS540A/RPLS541A Menu flowchart Organigramme des menus Organigrama de los menus Flowchart shows default settings Legend / Legende / Leyenda Le diagramme contient les réglages par défaut. El diagrama contiene los ajustes por defecto. Briefly press this button to go to preceding menu or setting.
  • Page 8 SANTA ROSA -122 SANTO DOMINGO HUNTSVILLE SAVANNAH VICTORIA -123 INDIANAPOLIS SEATTLE -122 WHITEHORSE -135 JACKSON SHREVEPORT WINDSOR JACKSONVILLE SOUTH BEND WINNIPEG KANSAS CITY SPOKANE -117 KNOXVILLE YELLOWKNIFE -114 SPRINGFIELD (IL) LAKEWOOD -105 SPRINGFIELD (MA) 69-2454EFS-07 RPLS540A/RPLS541A Printed in USA 04/2022...

Ce manuel est également adapté pour:

Rpls541a