Télécharger Imprimer la page

Kichler Design Pro LED Directives D'installation

Luminaire pour aménagement inerte, conforme à ansi/ul std.1838. certifié pour csa std. c22.2 no. 250.7

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

3169056
SAFETY INSTRUCTIONS
READ THIS FIRST
KEEP THESE INSTRUCTIONS
This fixture is intended for installation in accordance with the National
Electric Code (NEC) and Local code specifications. Failure to adhere to
these codes and instructions may result in serious injury and/or property
damage and will void the warranty.
1) WARNING: This fixture is not to be installed within 10 feet (3M) of a pool,
spa or fountain. . EXCEPTION: When the power unit is connected to a
GFCI protected branch circuit, the power unit has the option of being
mounted no less than 5 feet (1.52m) from a pool or spa.
2) This fixture is to be used only with a power unit (transformer) rated a
maximum of 300 W (25 AMPS) 15 volts.
3) The 18AWG fixture wire is not intended for direct burial.
4) Direct burial rated wire is to be buried a minimum of 6" (152mm) beneath
the surface of the ground. NOTE: If additional Direct Burial wire is
needed, contact your local Kichler® landscape distributor.
8 GA wire can be purchased in length of 250' (76 M), 15503-BK.
10 GA wire can be purchased in length of 250' (76 M), 15504-BK.
12 GA wire can be purchased in lengths of 100' (30 M), 15501-BK;
250' (76 M), 15502-BK; 500' (152M), 15505-BK; and 1000' (304 M),
15506-BK.
5) Wiring connections must be made with approved/listed wire connection
device(s) suitable for the application. Do not exceed manufacturers' wiring
combination specifications for size and quantity of conductors.
WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW
VOLTAGE), CARE SHOULD BE TAKEN TO KEEP CLEAR OF POTENTIALLY
COMBUSTIBLE MATERIALS.
WHEN MAINTAINING THE FIXTURES, BE SURE TO REMOVE LEAVES, PINE
NEEDLES, GRASS CLIPPINGS, MULCH, OR ANY DEBRIS THAT HAS ACCUMU-
LATED ON THE LIGHT BULB, LENS, OR BODY OF THE FIXTURE.
CAUTION – RISK OF SHOCK – Disconnect Power at the main circuit
breaker panel or main fuse box before starting and during the installa-
tion.
INSTALLATION OF 16100, 16101, 16102 or 16103
on BRICK or MASONRY WALL (SEE FIG. A)
1) Turn off power.
2) Determine the desired location for each fixture before construction of wall
is started. (NOTE: Notch cut in steel bracket is center of fixture for
alignment purposes)
3) Route the fixture wire through the wall to the main low voltage supply
cable using standard masonry procedures. A "V" shaped notch can be cut
into the hardscape material to aide in wire management if desired.
Note: It is recommended to leave a loop of wire accessible if it becomes
necessary to relocate fixture in the future.
4) Insert stainless steel mounting plate in between layers of hardscape
material. The use of adhesive or mortar (not provided) to secure the fixture
in place is optional. It may be best to adjust fixture before securing
permanently.
5) If adjustment of light fixture is desired follow instructions below.
6) Connect fixture wires to main low voltage supply cable using UL approved
connectors
ADJUSTMENT of 16100, 16101, 16102 or 16103 on BRACKET
(SEE FIG. A)
1) Turn off power.
2) Disassemble fixture by loosening screws which hold fixture to bracket at
least three turns.
3) Adjust tilt of the fixture to desired position.
4) Reassemble fixture by tightening both screws to bracket ensuring fixture
no longer moves. (NOTE: Over tightening screw may cause damage to
mounting bracket)
5) Turn on power.
6) If further adjustment is needed repeat steps 1 through 5
INSTALLATION of 16100, 16101, 16102 or 16103
off BRACKET/onto WOOD
1) Turn off power.
2) Determine the desired location for each fixture (NOTE: Notch cut in steel
bracket is center of fixture for alignment purposes)
3) Drill 1/8" Pilot holes in desired mounting location. The two holes in bracket
before the 90° can be used as a stencil for locating purposes.
(SEE FIG. B)
4) Disassembled light fixture by removing #10x32 screws which hold clamps
to bracket. (NOTE: Clamps may separate from light fixture body, it is
recommended to disassemble one side at a time to avoid losing parts)
5) Guide #6 Wood screws (supplied) into end clamps. Plastic spacer
(supplied) can be used to hold pieces together. (SEE FIG. C)
6) Attach end clamps to rotation features of fixture and align with pilot holes.
7) Reassemble fixture by tightening screws ensuring light fixture no longer
moves.
8) If adjustment to light fixture is needed loosen screws, adjust position and
retighten.
9) If no adjustment will be required, fixture can be installed in alternate
direction to provide flush appearance when installed.
(SEE FIG. C ALTERNATE)
Date Issued: 1/17/18
CONFORMS TO ANSI/UL STD.1838
CERTIFIED TO CSA STD. C22.2 NO. 250.7
Kichler® Design Pro LED
Hardscape Fixture Installation Instructions
Models: 16100XXXXX, 16101XXXXX,
16102XXXXX, 16103XXXXX,
CAUTION
For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page
Para informacion de la garantia por favor visite: www.landscapelighting.com/portal/warranty_page
866-558-5706
We're here to help
Hrs: M-F 9am to 5pm EST
IS-16101-US

Publicité

loading

Sommaire des Matières pour Kichler Design Pro LED

  • Page 1 Do not exceed manufacturers’ wiring combination specifications for size and quantity of conductors. CAUTION WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW VOLTAGE), CARE SHOULD BE TAKEN TO KEEP CLEAR OF POTENTIALLY COMBUSTIBLE MATERIALS.
  • Page 2 GRAPA DE RETENCIÓN GRAPA DE RETENCIÓN PRECAUCION CUANDO SE INSTALE SISTEMAS DE ALUMBRADO KICHLER PARA JARDINES (YA SEA DE VOLTAJE DE LINEA O CON VOLTAJE BAJO) SE DEBE TENER MUESCA DE CENTRADO PLANTILLA DE...
  • Page 3 CAUTION WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW VOLTAGE), CARE SHOULD BE TAKEN TO KEEP CLEAR OF POTENTIALLY COMBUSTIBLE MATERIALS. WHEN MAINTAINING THE FIXTURES, BE SURE TO REMOVE LEAVES, PINE NEEDLES, GRASS CLIPPINGS, MULCH, OR ANY DEBRIS THAT HAS ACCUMULATED ON THE LIGHT BULB, LENS, OR BODY OF THE FIXTURE.
  • Page 4 CONFORME À ANSI/UL STD.1838 We’re here to help CERTIFIÉ POUR CSA STD. C22.2 NO. 250.7 Hrs: M-F 9am to 5pm EST Kichler® LED Design Pro Directives d’installation du luminaire pour aménagement inerte P/N: 16100XXXXX, 16101XXXXX, 16102XXXXX, 16103XXXXX, 3169056 LIRE TOUTES LES DIRECTIVES AVEC SOIN AVANT DE COMMENCER L’INSTALLATION...

Ce manuel est également adapté pour:

16101azt3016101gry3016102azt2716100gry2716100bkt2716100cbr27 ... Afficher tout