SPECIFICATIONS
Blade Type: Fits most industry standard blades
Batteries: CAM-10 Use 2 LR44 button cell batteries
Operating Range: 50-600 VAC, 50-60 Hz
Voltage Indicators: Audible & Visual Alert
Operating Temperature: 32-122°F (0-50°C)
Storage Temperature: 0°F (-18°C) to 156°F (70°C)
Humidity: 80% RH maximum below 86 °F(30 °C),
50% RH maximum above 86 °F (30 °C)
Altitude: Up to 6561 feet (2000 meters)
Safety: For indoor use and in accordance with over voltage category III
Pollution degree 2
Intended Use: Non-contact AC voltage detection
Serial No: See interior of battery cover
CLEANING
Use clean, dry cloth. Do not use any type of solvent.
BEFORE USE
READ ALL OPERATING INSTRUCTIONS BEFORE USE. FOR INTENDED USE
ONLY. Protection provided by this product may be impaired if used with accessories
not provided by the manufacturer or if used as in a manner other than specified within.
!
!
WARNING: The blades are very sharp. Handle this product and spare or
replacement blades with care. The blades may break and cause injury. Wear
protective clothing.
WARNING: ALWAYS wear safety goggles when using this product.
!
!
WARNING: Never use knife on or near live electrical circuits.
!
WARNING: To be used by trained person only. High voltage AC and DC circuits
are dangerous. Use extreme caution and use as intended when testing potentially
live circuits. Risk of Electrocution.
!
WARNING: This product should be used to test or detect insulated wires and
terminals but should not be used to contact Live Circuits. This tester will not
detect voltage in wires that are electrically shielded by metal conduit or grounded
enclosures. Risk of Electrocution.
OPERATION
Before use, test the batteries of the CAM-10 tester by pressing the button on the
tester marked PRESS. A momentary audible tone and flash of the light are an
indication that the unit is working.
!
WARNING: Always test on known live circuit before use.
To test for voltage:
1. Hold the knife with your thumb on the CAM-10 tester button
marked PRESS, keeping hands and fingers well away
from the sensor (red end).
2. Press down and hold the test button on the tester.
A momentary alert indicates the unit is working.
3. Place the sensor (red end) near the wire or device to be
tested. Maintain a minimum distance of 0.5 mm from
contacting the wire or device to be tested. If voltage
greater than 50 VAC is present, the tester light and
tone will activate rhythmically at 10 to 15 cycles second.
To detach the tester from the knife, apply force to the
tester near the Gardner Bender logo and slide the
tester from the holding slot. The tester can be used
to test for voltage after it is detached per instructions
within. Hold the tester as shown, keeping hands and fingers
well away from the sensor (red end).
CAM-10 BATTERY REPLACEMENT
Remove the Phillips
head screw from the bottom of the CAM-10 tester. Lift off the
®
battery cover from the top of the tester. Insert 2 LR44 batteries in the orientation
indicated on the side of the battery cover. Replace cover and screw.
To change the blade, hold the knife securely.
1. Slide the blade button down and forward.
2. Press and hold the blade release button
3. Remove blade. Rotate blade 180°
for reuse or insert a new blade.
4. Release the blade release button.
Check for securely held blade.
To rip Romex
1. Insert cable through the ripping station
2. Twist your wrist to force the ripping blade
to penetrate cable jacket.
3. Apply a steady force of the knife toward the free
end of the cable.
To strip wire, hold the knife securely. (RKT-21 only)
1. Slide the blade button down and back
2. Place wire in stripping station
3. Slide the blade button down and forward against wire.
4. Pull wire out against blade to strip wire.
Patents Pending
Limited Lifetime Warranty limited solely to repair or replacement; no warranty or
merchantability or fitness for a particular purpose. Product is warrantied to be free
of defects in materials and workmanship for the normal life of the product. In no
event shall Gardner Bender be liable for incidental or consequential damage.
RKT-10, RKT-20, RKT-21
Cuchilla de electricista
CAM-10
Probador de voltaje sin cantacto
SÍMBOLOS
Este equipo tiene doble aislamiento con respecto a circuitos energizados
!
!
Atención, consulte los documentos adjuntos
ESPECIFICACIONES
Tipo de hoja: Sirve para la mayoría de las hojas estándar en la industria
Baterías: El modelo CAM-10 usa 2 baterías de botón LR44
Rango operativo: 50-600 VCA, 50-60 Hz
Indicadores de voltaje: Alerta sonora y visual
Temperatura operativa: 0-50°C
Temperatura de almacenamiento: -18°C (0°F) a 70°C (156°F)
Humedad: 80% HR máxima bajo 30 °C (86 °F),
50% HR máxima sobre 30 °C (86 °F)
Altitud: Hasta 2000 metros.
Seguridad: Para uso en interiores y conforme a la categoría III de sobrevoltaje
Grado de contaminación 2
Uso previsto: Detección de voltaje CA sin contacto
Núm. de serie: Vea el interior de la cubierta de la batería
LIMPIEZA
Use un paño limpio y seco. No use ningún tipo de solvente.
ANTES DEL USO
LEA TODAS LAS INSTRUCCIONES OPERATIVAS ANTES DEL USO. SÓLO
PARA EL USO PREVISTO. La protección provista por este producto puede verse
afectada si se usa con accesorios no suministrados por el fabricante o si se usa de
una manera diferente de la especificada adentro.
!
!
ADVERTENCIA: Las hojas son muy filosas. Maneje con cuidado este producto y
las hojas de repuesto o reemplazo. Las hojas pueden quebrarse y causar lesiones.
Use ropa protectora.
ADVERTENCIA: SIEMPRE use anteojos de seguridad al utilizar este producto.
!
!
ADVERTENCIA: Nunca use la cuchilla en circuitos eléctricos energizados ni cerca
de ellos.
!
ADVERTENCIA: Sólo para el uso de personal capacitado. Son peligrosos los
circuitos de CA y CC de alto voltaje. Tenga sumo cuidado y utilice de la manera
prevista al probar circuitos potencialmente energizados. Riesgo de electrocución.
!
ADVERTENCIA: Este producto debe usarse para probar o detectar cables aislados
y terminales pero no para hacer contacto con circuitos energizados. Este probador
no detecta el voltaje en cables que tienen blindaje eléctrico mediante portacables
de metal o cierres puestos a tierra. Riesgo de electrocución.
OPERACIÓN
Antes de usar, pruebe las baterías del probador CAM-10 oprimiendo el botón en el
probador que está marcado PRESS. Un tono audible momentáneo y un destello de
luz son indicaciones de que la unidad está funcionando.
!
ADVERTENCIA: Siempre pruebe en un circuito energizado conocido antes de usar.
Para probar el voltaje:
1. Sostenga la cuchilla con el pulgar en el botón del probador CAM-10 marcado
PRESS, manteniendo las manos y los dedos bien alejados del sensor
(extremo rojo).
®
, hold the knife securely. (RKT-21 only)
INSTRUCCIONES
OPERATIVAS
Patentes pendientes

Publicité

loading

Sommaire des Matières pour Gardner Bender RKT-10

  • Page 1 SYMBOLS of defects in materials and workmanship for the normal life of the product. In no event shall Gardner Bender be liable for incidental or consequential damage. This equipment has double insulation with respect to live circuits Attention, consult the accompanying documents...
  • Page 2 être exempt de défaut de matériau et de fabrication pour la durée normale Altitude : Jusqu’à 2000 mètres du produit. Gardner Bender ne serait dans aucun cas tenue responsable des Sécurité : Pour une utilisation à l’intérieur et conforme aux normes de catégorie III dommages indirects ou accessoires.

Ce manuel est également adapté pour:

Rkt-20Rkt-21Cam-10