HydroSensor I & II Moisture Probes
Phone: 800-932-3030 Fax: 360-757-7950
R E A D A N D S A V E T H E S E I N S T R U C T I O N S
NOTICE: The sensor points of the
HydroSensor probe are extremely sharp.
Take care when collapsing the telescoping
tubes to avoid the points extending by accident.
This could cause injury. Always retract the probe
points into the shaft when not in use.
BEFORE YOU BEGIN
Warranty registration
Visit warranty.LegendBrandsRestoration.com to register your
purchase. Registration allows us to better assist you with us-
ing, maintaining or servicing your equipment and to contact
you in case we have important safety information concerning
your Dri-Eaz product. If you determine service is required,
have your equipment model, serial number and original proof
of purchase available and call your distributor for assistance
with obtaining a return material authorization (RMA).
INTRODUCTION
The HydroSensor Moisture Probes I & II are designed to detect
moisture in carpets, cushion, floors, walls, furniture and other
materials. When the probe tips are pushed into materials to
penetrate the surface, an electric current is sent between the
probes. The amount of moisture present in the material deter-
mines how easily the electrical current passes from one probe
to the other.
When moisture is present in a material, the light on the Hy-
droSensor will flash and the transducer will beep. The faster
the rate of flashing and beeping, the higher the level of mois-
ture.
The 7/8 in. probe tips are long enough to penetrate shag car-
pets, cushion, and flooring materials. With care, the HydroSen-
sor can also be used to find moisture in furniture, walls, and
ceiling materials.
The HydroSensor will also detect the presence of urine resi-
dues. This is because urine salts attract and hold enough
moisture to be detected. A black-light is recommended to con-
firm that urine is present.
07-00315F F245, F251
Owner's Manual
15180 Josh Wilson Road, Burlington, WA 98233
Conveniently detect moisture in carpets, pads, furniture, walls and other materials.
Patents: http://www.LBpatents.com
Models F245, F251
LEGEND BRANDS, INC.
http://LegendBrandsRestoration.com
OPERATION
1.
When using the HydroSensor II, first extend the shaft.
Grasp the smaller-diameter tube and slide it out until the
spring button pops into place.
2.
Extend the sensor points at the bottom of the probe. Loosen
the black plastic knob. Push it down and around the S-
shaped slot, then tighten the knob to lock in position.
3.
Test the unit by placing your fingers across the shaft of the
points. The indicator lamp will light and the unit will beep.
4.
Probe the suspected moisture area with the points. Flash-
ing and beeping indicates that carpet and/or pad are wet. A
faster rate of beeping/flashing indicates a higher level of
moisture.
5.
Take care not to apply too much force on the probe. Excess
force may damage the tips or telescoping tubes.
6.
Always retract the sensor points when not in use.
1
Legend Brands, Inc.

Publicité

loading

Sommaire des Matières pour Dri-Eaz HydroSensor I

  • Page 1 Dri-Eaz product. If you determine service is required, Take care not to apply too much force on the probe. Excess have your equipment model, serial number and original proof force may damage the tips or telescoping tubes.
  • Page 2 If the probe tips become dull, they may be resharpened with a Probe tips 7/8 in. nickel plated steel file. If points need replacement because of excessive wear, con- tact Dri-Eaz for a replacement kit. Shaft Stainless steel Battery Replacement...
  • Page 3: Antes De Comenzar

    Procure no aplicar mucha fuerza sobre la sonda. El exceso Las sondas de humedad HydroSensor I y II están diseñadas para de fuerza podría dañar las puntas o los tubos telescópicos. detectar la humedad en alfombras, almohadones, pisos, paredes, Siempre repliegue las puntas del sensor hacia adentro del muebles y otros materiales.
  • Page 4 Si necesita reemplazarlas por uso excesivo, póngase en Puntas de la sonda 7/8 pulgadas de acero niquelado contacto con Dri-Eaz para conseguir un kit de reemplazo. Acero inoxidable Reemplazo de batería El HydroSensor funciona con la corriente de una batería de 9 vol- Manija Moldeada a inyección...
  • Page 5: Avant De Commencer

    Testez l’appareil en plaçant vos doigts sur la tige des portantes concernant la sécurité de votre produit Dri-Eaz. Si pointes. Le témoin s’allume et l’appareil émet un signal son- vous déterminez qu’un entretien est requis, ayez en main votre ore.
  • Page 6: Entretien

    Pointes de Acier nickelé de 7/8 po de long réaffutées avec une lime. Si les pointes doivent être remplacées sonde en raison d’une usure excessive, contactez Dri-Eaz Products Arbre Acier inoxydable pour obtenir une trousse de remplacement. Remplacement de la pile Poignée...

Ce manuel est également adapté pour:

Hydrosensor iiF245F251