No: 1025789 - 0320
Catalog Number(s) • Numéro(s) de Catalogue • Número(s) de Catálogo: XDU50A, XDU50AHNDL & XDU30AHNDL
IMPORTANT:
Please read all instructions before
beginning installation
Legrand electrical systems conform to and
should be properly grounded in compliance with
requirements of the current National Electrical
Code or codes administered by local authorities.
All electrical products may present a possible
shock or fire hazard if improperly installed
or used. Legrand electrical products may
bear the mark of a Nationally Recognized
Testing Laboratory and should be installed
in conformance with current local and/or the
National Electrical Code.
Thank you for purchasing Legrand's Temporary Power Distribution Center. This unit provides state of the art protection for your temporary
power needs via Legrand's exclusive GFCIs*
Mercid'avoir acheté le coffret de distribution électrique provisoire Legrand. Cette unité fournit une protection d'avant-garde à vos besoins
d'alimentation temporaire à l'aide du module de ) et de disjoncteurs de fuite de terre (GFCI).
Graciaspor comprar la Unidad de distribución de energía provisoria de Legrand. Esta unidad brinda una protección de avanzada para sus
necesidades de energía provisoria mediante y los interruptores con detección de falla a tierra (GFCI).
Manual
Keep this manual for future reference
Manuel
Conserver ce manuel pour référence future
Manual del producto
Guarde este manual para consultar más adelante.
Model Number
Numéro de modèle
Número de modelo:

WIREMOLD
Temporary Power
Distribution Center
Coffret de distribution
électrique provisoire
Unidad de distribución de
energía provisoria
Installation Instructions • Notice d'Installation• Instrucciones de Instalación
IMPORTANT :
Veuillez lire l'ensemble des
instructions avant de commencer
l'installation.
Les systèmes électriques Legrand sont
conformes au Code National de l'électricité
(National Electrical Code) ou aux codes
locaux en vigueur et doivent être mis à la terre
conformément à ces codes.
Tous les produits électriques peuvent présenter
un risque d'électrocution ou d'incendie s'ils ne
sont pas installés ou utilisés correctement. Les
produits électriques Legrand peuvent porter la
marque d'un laboratoire reconnu et doivent être
installés conformément au Code national de
l'électricité et/ou aux codes locaux en vigueur.
Serial Number
Numéro de série
Número de serie:

®
IMPORTANTE:
Lea todas las instrucciones antes
de comenzar la instalación.
Los sistemas eléctricos Legrand cumplen con
los requisitos del Código Eléctrico Nacional
(National Electrical Code, NEC) actual o con los
códigos impuestos por las autoridades locales y
deben conectarse a tierra consecuentemente.
Todos los productos eléctricos pueden
presentar un riesgo de descarga o incendio
si se los instala o utiliza incorrectamente. Los
productos eléctricos Legrand pueden llevar la
marca de un laboratorio de pruebas reconocido
a nivel nacional y se deben instalar conforme al
código local en vigencia o al Código Eléctrico
Nacional.
Date put into service
Date de mise en service
Fecha de puesta en servicio:


Publicité

Table des Matières
loading

Sommaire des Matières pour LEGRAND WIREMOLD XDU50A

  • Page 1 Nacional. l'électricité et/ou aux codes locaux en vigueur. Thank you for purchasing Legrand’s Temporary Power Distribution Center. This unit provides state of the art protection for your temporary power needs via Legrand’s exclusive GFCIs* Mercid’avoir acheté le coffret de distribution électrique provisoire Legrand. Cette unité fournit une protection d’avant-garde à vos besoins d’alimentation temporaire à...
  • Page 2 Basic Operating Instructions Instructions de base Instrucciones de funcionamiento básicas Make sure no equipment is plugged into power center 1. Make sure all circuit breakers located under the clear protective door are turned off. 2. Connect main power cord to unit 3.
  • Page 3 à la terre avant toute utilisation. Interruptor con detección de falla a tierra (GFCI) • Disponible en el número de modelo XDU50A de Legrand. • Protección de GFCI reconocida por UL para aplicaciones de energía provisorias que brinda una protección neutra abierta: se dispara cuando se pierde la conexión neutra.
  • Page 4: Catalog Number

    Temporary Power Distribution Center - Selection Guide Catalog Number XDU50A XDU50AHNDL XDU30AHNDL Listings cETLus Listed Per UL1640 & cETLus Listed Per UL1640 & cETLus Listed Per UL1640 & CSA C22.2 CSA C22.2 CSA C22.2 Electrical Rating 50A; 125/250V; 12,500W 50A; 125/250V; 12,500W 30A;...
  • Page 5: Coffret De Distribution Électrique Provisoire - Guide De Sélection

    Coffret de distribution électrique provisoire - Guide de sélection Numéro de catalogue XDU50A XDU50AHNDL XDU30AHNDL Listages Certifié cETLus selon UL1640 & Certifié cETLus selon UL1640 & Certifié cETLus selon UL1640 & CSA C22.2 CSA C22.2 CSA C22.2 Coefficient électrique 50A; 125/250V; 50A;...
  • Page 6: Número De Catálogo

    Unidad de distribución de energía provisoria – Guía de selección Número de catálogo XDU50A XDU50AHNDL XDU30AHNDL Listados cETLus clasificado conforme cETLus clasificado conforme cETLus clasificado conforme a la normativa UL1640 y CSA a la normativa UL1640 y CSA a la normativa UL1640 y CSA C22.2 C22.2 C22.2...
  • Page 7: Troubleshooting Guide

    Trouble Shooting Guide Symptom Possible Cause Suggested Action No Power to ALL Outlets No Main power Check power input source Circuit Breakers OFF Set to ON GFCI Modules OFF Reset Modules No Power to ONE Outlet Circuit Breaker tripped or OFF RESET / Set to ON GFCI Module OFF Reset Module...
  • Page 8 Notes Remarques Notas No: 1025789 - 0320 860.233.6251 1.877.BY.LEGRAND www.legrand.us © Copyright 2020 Legrand All Rights Reserved. www.legrand.ca © Copyright 2020 Tous droits réservés Legrand. © Copyright 2020 Legrand Todos los derechos reservados.