Télécharger Imprimer la page

Liens rapides

Owner's Instruction and Operation Manual
Model Number:
AP60
Report #: F20-571
Certified to ASTM E1509-12 (2017)
and Certified to ULC-S627-00-REV1
Mobile Home Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result.
For your safety, follow the installation instructions. Never use make-shift
compromises during the installation of this heater. Contact local building or
fire officials about permits, restrictions and installation requirements in your
area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury,
or even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
Owners Manual for
PDF provided by
Stove & Grill Parts For Less
R
Ashley AP60
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to
www.P65warnings.ca.gov
853240J-0204k
Ph. 800-750-2723
loading

Sommaire des Matières pour United States Stove Company Ashley AP60

  • Page 1 State of California to cause emissions standards. cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 2 This app is available only Text to 423-301-5624 or; on the App Store for iPhone and iPad. Email us at: Search US Stove. Save your receipt with customerservice@usstove.com your records for any claims. © 2021 United States Stove Company...
  • Page 3 Signed: ___________________________________ Print Name: ______________________________ Date: _____________ Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE © 2021 United States Stove Company...
  • Page 4 THE HEATER. DO NOT ROUTE THE CORD IN by a qualified NFI (US) or WETT (Canada) technician. FOOT TRAFFIC AREAS OR PINCH THE CORD To find the nearest qualified installer, go to: UNDER FURNITURE. https://nficertified.org, https://www.wettinc.ca/ © 2021 United States Stove Company...
  • Page 5 6” 153 mm G Wall To Corner Of Unit 2” 51 mm Front to Stove 18” 458 mm H Ceiling Height To Floor 60” 1524 mm J Ceiling Height To Unit 27” 686 mm © 2021 United States Stove Company...
  • Page 6 In addition to the previously detailed installation THE WAY EXPLAINED IN THIS MANUAL, IT requirements, mobile home installations must WILL NOT FUNCTION PROPERLY. meet the following requirements: • This stove must be securely fastened to the floor © 2021 United States Stove Company...
  • Page 7 The pellet vent pipe is designed to disassemble for cleaning and should be checked several times during the burning season. The pellet vent pipe is not furnished with the unit and must be purchased separately. © 2021 United States Stove Company...
  • Page 8 6. Install the appropriate length of exhaust vent combustible construction is desired, the installation pipe into the wall thimble. See steps 11 and 12 must conform to CAN/CSA-B365. when determining the correct length of exhaust vent to use. © 2021 United States Stove Company...
  • Page 9 4ft (1.22m) to make the system more an offset is required, it is better to install 45-degree stable. If you live in an area that has heavy snowfall, elbows rather than 90-degree elbows. © 2021 United States Stove Company...
  • Page 10 3.5 minutes, off for 1 minute. During the remainder fill with too much fuel and the fire will smother out. of the start-up period, the auger motor operates To much air will result in a flame that is overactive © 2021 United States Stove Company...
  • Page 11 The draft fan (exhaust) will come on as soon as the “ON” button is pressed. The fan will automatically adjust its speed in accordance to the heat range setting. However, this speed can be manually © 2021 United States Stove Company...
  • Page 12 T’Stat requires more heat, the unit will begin to feed pellets at the preselected heat setting ranging from “1” to “5”. Use 18 gauge, 2 conductor wire © 2021 United States Stove Company...
  • Page 13 We cannot accept ATTENTION: responsibility for damage due to poor quality pellet. THIS APPLIANCE IS DESIGNED FOR THE USE OF PELLETIZED FUEL THAT MEET OR EXCEED THE STANDARD SET BY THE PELLET FUEL INSTITUTE (PFI). © 2021 United States Stove Company...
  • Page 14 1. To achieve a “low burn” your stove will run until the stove cools. This will take 30 minutes should be set on setting 1. or longer depending on the heat remaining in © 2021 United States Stove Company...
  • Page 15 Some regular vacuum Your stove is equipped with a high temperature cleaner (i.e. shop vacs) may leak ash into the room. thermodisc. This unit has a manual reset DO NOT VACUUM HOT ASH. © 2021 United States Stove Company...
  • Page 16 Burning wood naturally produces smoke and be removed to reduce the risk of a chimney fire. carbon monoxide(CO) emissions. CO is a poisonous Inspect the system at the stove connection and gas when exposed to elevated concentrations © 2021 United States Stove Company...
  • Page 17 NOT perform the cleaning while the glass is HOT. Do not attempt to operate the unit with broken glass. Replacement glass may be purchased from your U.S. Stove dealer. If the glass is broken, follow these removal procedures: © 2021 United States Stove Company...
  • Page 18 Chamber Ashes Check Empty Interior Vacuumed Chambers Combustion Vacuumed Blower Blades / Brushed Convection Vacuumed Blower Impeller / Brushed Vent System Cleaned Gaskets Inspected Glass Wiped Cleaned Hopper (end of Empty & season) Vacuumed © 2021 United States Stove Company...
  • Page 19 ATTENTION: THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL. © 2021 United States Stove Company...
  • Page 20 Flashing Automatic Mode - This indicates that settings, press and hold the AUX UP and AUX the stove is in normal operation and is running in DOWN buttons together for three seconds. the automatic mode. However, either the draft fan © 2021 United States Stove Company...
  • Page 21 REPAIR PARTS © 2021 United States Stove Company...
  • Page 22 Call 1-800-750-2723 Ext 5051 or Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ASHLEY PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM ASHLEY. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2021 United States Stove Company...
  • Page 23 Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once this information has been gathered you can contact customer service by phone 1-800-750-2723 Ext 5051 or Email parts@usstove.com. Model Information Model Number Serial Number © 2021 United States Stove Company...
  • Page 24 Engineer Name: _______________________________ Engineer Name: _______________________________ License No.: ____________________________________ License No.: ____________________________________ Company: _____________________________________ Company: _____________________________________ Telephone No.: _________________________________ Telephone No.: _________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: _______________________________ Items Replaced: _______________________________ © 2021 United States Stove Company...