Eaton Dimmer
3-Way Wiring
Instructions
Setup Guide
LD06P - Decorator Dimmer
LS06P - Slide Dimmer
Scan QR code
for product
information.
EIS-0314-EFS (REV. A)
Prepare
1.
Shut off circuit breaker before installation.
ON
OFF
2. You will need:
Included in box:
Not included in box:
Voltage tester
or
Screwdriver
LD06P
LS06P
Decorative
Wire nuts
Dimmer
Dimmer
wallplate
Additional information
WARNINGS AND CAUTIONS
• Turn OFF circuit breaker/remove fuse(s) and test if power is OFF before
installation
• Never wire any electrical device with power ON
• Contact a licensed electrician if you are unsure about any part of these
instructions
• The device may not work or may be damaged if wired incorrectly, or wiring
with power ON. Warranty may be voided.
• CAUTION: To reduce the risk of overheating and possible damage to this
device or other equipment, do not install to control a receptacle, motor-
operated appliance, or a transformer-supplied appliance.
• Contact a licensed electrician if bare copper or green ground connection
are not present in wall box.
• Use only #14 or #12 copper wire rated for at least 75°C. DO NOT USE
ALUMINUM WIRE
• Use only with 120V/AC 60Hz and with permanently installed fixtures
• Do not exceed maximum rating indicated on the device
• Must be installed and used in accordance with all national and local
electrical codes
• Outlet box must be at least 3" x 2" x 2-1/2" and wired in accordance with
NEC article 314 box fill requirements
Check
3. Remove wallplate and unscrew old device.
• Make sure the power is off using voltage tester,
non-contact voltage tester, or multimeter.
Warning! Risk of injury
(See Fig. 1 below)
or death. Contact an
• If power is still on, there might be another circuit
electrician if you are
unsure about any part
breaker powering this terminal. Switch terminal off
of these instructions.
and retest.
Fig. 1
4. Indentify GROUND, NEUTRAL (if present),
TRAVELERS, and COMMON/HOT wires for
future use.
GROUND
NEUTRAL
TRAVELERS
HOT/COMMON
2"
2.5"
3"
loading

Sommaire des Matières pour Eaton LD06P

  • Page 1 2.5” 2. You will need: Setup Guide Included in box: Not included in box: Fig. 1 Voltage tester 3” Screwdriver LD06P - Decorator Dimmer LD06P LS06P Decorative Wire nuts Dimmer Dimmer wallplate LS06P - Slide Dimmer 4. Indentify GROUND, NEUTRAL (if present),...
  • Page 2 For additional troubleshooting, visit Eaton.com/Dimming or contact us at 1-877-386-2273, Option 5 Decorator Dimmer - LD06P then Option 3 for more help. Wire connecting to bottom of device is HOT/COMMON. Wires connecting to side of device are TRAVELERS. For Eaton Tech Support: Bare wire is GROUND.
  • Page 3 Variateur décorative Informations complémentaires AVERTISSEMENTS ET PRÉCAUTIONS • Coupez le disjoncteur/enlevez le(s) fusible(s) et vérifiez qu’il n’y a pas de courant avant l’installation. LD06P - Variateur décoratif 4. Identifiez les fils de TERRE, NEUTRE (le cas • Ne jamais brancher un appareil électrique lorsque l’alimentation est sous LS06P - Variateur coulissant tension. échéant), VOYAGEURS et COMMUN/SOUS • En cas de doute concernant ces instructions, contactez un électricien CHAUD pour utilisation ultérieure.
  • Page 4 3 pour obtenir de l’aide supplémentaire. Le fil branché en haut de l’appareil est le fil de phase (commun). Pour le soutien technique Eaton : Les fils connectés au bas de l’appareil sont les fils navette. Techsupport@eaton.com Le fil nu est le fil de terre.
  • Page 5 • Nunca conecte ningún dispositivo eléctrico con la corriente encendida. uso futuro. LD06P - Regulador decorativo • Si tiene dudas sobre alguna parte de estas instrucciones, comuníquese con un electricista autorizado. LS06P - Regulador deslizante •...
  • Page 6 Para obtener ayuda adicional para la resolución de problemas, visite Eaton.com/Dimming Regulador decorativo - LD06P o comuníquese con nosotros al 1-877-386-2273, El cable conectado a la parte superior del dispositivo opción 5 y luego opción 3 para obtener más ayuda.

Ce manuel est également adapté pour:

Ls06p