Correcting Errors
2. Adjust or replace the switch if necessary.
E19 WATER SENSOR DID
NOT SENSE GOODS
E20 PRESS CODE XX
IS INVALID
E21 PRESS SHOULD BE
EMPTY
The tunnel transferred a cake which was improperly coded as an empty pocket. Check empty
pocket programming in the tunnel and make the necessary corrections.
The ram full down switch is malfunctioning or is out of adjustment.
1. Ensure proper actuation of the switch per "Setting Single Stage Press Proximity Switch Posi-
tions" in the service manual.
2. Adjust or replace the switch if necessary.
E22 COINC EYE
BLOCKED
There are goods on the end of the COINC belt blocking the photoeye. Clear the goods from
the belt and restart the press.
The COINC belt is slipping or failed to run. Inspect and repair the belt as necessary.
The COINC photoeye (COINC loaded input) is malfunctioning or is out of adjustment.
1. Ensure proper actuation of the photoeye.
2. Adjust or replace the photoeye if necessary.
E23 RAM NOT FULLY
IN CAN
A double or oversized load is in the can. Remove some of the goods from under the ram using
the gaff hook supplied by the factory.
34
The water sensor input was not made during loading and the load
was not an empty. Press
Indicates the press received a press code from the loading device
for a non-existent formula. This is usually due to a data entry er-
ror. Pressing
clears the error and puts the press in manual
mode. Return to automatic mode and verify the cake data.
Indicates the ram did not clear the ram full down proximity
switch, suggesting that there is a load in the can when the loading
device indicated an empty pocket. Pressing
and puts the press in manual mode. This error may be caused by
the following conditions:
Applies only to machines equipped with a COINC. Indicates the
COINC photoeye did not clear during discharge. This error is en-
abled only when the configure decision Time for Cake to Clear
COINC Eye is set to a non-zero value. Pressing
error and puts the press in manual mode. This error may be
caused by the following conditions:
Indicates the ram failed to clear the unload point when the press
attempted to lower the ram, suggesting that the ram is not fully in
the can. The press makes two attempts to lower the ram before
signaling the error. Pressing
press in manual mode. This error may be caused by the following
conditions:
to return to automatic operation.
clears the error
clears the error and puts the
Pellerin Milnor Corporation
clears the