ILLUMINATOR™ EVFT
Fluorescent Luminaires
Installation & Maintenance Information
APPLICATION
Illuminator fluorescent luminaires are suitable for use in the following
hazardous (classified) areas as defined by the National Electrical Code
(NEC®), Canadian Electrical Code (CEC), and International
Electrotechnical Commission (IEC):
Class I Group D
Class II Groups E, F & G; Simultaneous Presence;
Class III, Simultaneous Presence
Illuminator fluorescent luminaires with suffix "GB" also suitable for
Class I, Groups B & C.
These fixtures are factory sealed; external seals are not required. The
T-Rating of the fixture must not exceed the ignition temperature of the
atmosphere in which it is to be operated. Refer to the fixture nameplate
for specific classification information and appropriate operating
temperature (T) rating.
To avoid the risk of fire, explosion, or electric shock, this
product should be installed, inspected, and maintained by a
qualified electrician only, in accordance with all applicable electrical
codes.
To avoid electric shock:
Be certain electrical power is OFF before and during installation and
maintenance.
Luminaire must be supplied by a wiring system with an
equipment grounding conductor.
To avoid burning hands:
Make sure lamp tube and lamp are cool when performing
maintenance.
INSTALLATION
Illuminator lighting fixtures are designed for operation only with the
lamp in a horizontal to base down position. Do not install in any
classified location where the marked operating temperatures exceed
ignition temperatures of hazardous atmospheres. Do not install fixture
in location where ambient temperature exceeds maximum ambient
temperature indicated on fixture nameplate. Keep tightly closed when
in operation.
NOTE: All threaded joints are "O" ring sealed for wet locations suitability.
Exercise care:
during assembly, to ensure threaded components are thoroughly
tightened against "O" rings.
during disassembly, to avoid accidental damage to the "O" ring.
1.
Loosen set screw in flange of lamp tube at main housing end.
2.
Position hands over lamp tube assembly. Remove lamp tube
assembly by threading counter-clockwise until disengaged.
Carefully slide off over ground plane.
IF 1143 • 05/03
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
WARNING
WARNING
WARNING
Copyright © 2003, Cooper Industries, Inc.
Illuminator fluorescent lighting fixtures are also suitable for use in wet
locations, marine locations and paint spray areas. They are designed for
use in industrial locations where moisture, dirt, and vibration may be a
problem.
Illuminator fixtures are for use with two or four "PL*", "BIAX†", or
"DULUX L‡" single-ended fluorescent lamps. The fixture ratings are 78
(2 lamp) or 156 watts (4 lamp). Fixture input voltage is 120 or 277 VAC.
Single-ended fluorescent lamps have operating characteristics similar to
conventional F40 fluorescent lamps, i.e. they are intended to be used in
ambient temperatures of 50°F (10°C) or more.
Illuminator fluorescent luminaires with suffix "GB" are installed in
the conduit system through the pendant hub only
* Trademark - Philips Lighting Corp.
‡ Trademark - Osram Corp.
® Registered Trademark - National Fire Protection Association
To avoid explosion:
Make sure the supply voltage is the same as the luminaire voltage.
Do not install where the marked operating temperatures exceed the
ignition temperature of the hazardous atmosphere.
Do not operate in ambient temperatures above those indicated on the
luminaire nameplate.
Install luminaire with lamp base up within 25º of vertical.
Use only the lamp and wattage specified on the luminaire
nameplate.
Use proper supply wiring as specified on the luminaire nameplate.
All gasket seals must be clean.
Before opening, electrical power to the luminaire must be turned off.
Keep tightly closed when in operation.
3.
Select the desired mounting configuration and then follow the
corresponding mounting instructions below.
NOTE: Allow the following spacing provisions for fixtures when
installing into conduit system:
• Removal of lamp tube assembly - 20 inches
• Removal of ballast housing - 3 inches
IF 1143
† Trademark - General Electric Co.
WARNING
Page 1

Publicité

loading

Sommaire des Matières pour Eaton ILLUMINATOR EVFT Serie

  • Page 1 ILLUMINATOR™ EVFT Fluorescent Luminaires IF 1143 Installation & Maintenance Information SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE APPLICATION Illuminator fluorescent lighting fixtures are also suitable for use in wet locations, marine locations and paint spray areas. They are designed for Illuminator fluorescent luminaires are suitable for use in the following use in industrial locations where moisture, dirt, and vibration may be a hazardous (classified) areas as defined by the National Electrical Code problem.
  • Page 2 PENDANT MOUNT FIXTURE WIRING WARNING All unused conduit openings must be plugged. Plug must engage a minimum of five full threads. Use PLG explosion-proof plugs supplied with the fixture. Ground Connection Remove ceiling mount bracket and screws from fixture housing, and discard.
  • Page 3 GUARD INSTALLATION / REMOVAL REFLECTOR INSTALLATION / REMOVAL Either an RAR1 right reflector or an RAL1 left reflector is appropriate for Retaining two lamp fixture. Four lamp fixture uses one RAR1 and one RAL1. Ridge PENDANT Place optional stainless steel guard(s) over lamp tube assembly(s) and press into place over retaining ridge.
  • Page 4 RELAMPING Install new ballast with ballast mounting bracket positioned as shown above. With screws aligned with groove above ballast, slide Disconnect power to fixture. ballast into housing. Feed all wires to channel below ballast mounting surface assuring wires are not pinched between ballast Remove reflector(s) and/or PG1 polycarbonate shield(s), if used.
  • Page 5 ILLUMINATOR™ EVFT Luminaires fluorescents IF 1143 Instructions d'installation et d'entretien CONSERVEZ CES INSTRUCTIONS POUR CONSULTATION FUTURE APPLICATION Les luminaires fluorescents Illuminator conviennent également à l'utilisation dans les emplacements mouillés et maritimes ainsi que dans Les luminaires fluorescents conviennent à une utilisation dans les zones des zones de peinture au pistolet.
  • Page 6 MONTAGE DU DISPOSITIF DE SUSPENSION INSTALLATION DES FILS DU LUMINAIRE AVERTISSEMENT Toutes les ouvertures de conduit inutilisées doivent être bouchées. Le bouchon doit être engagé sur un minimum de cinq pas de vis complets. Utiliser les bouchons antidéflagrants fournis avec le luminaire.
  • Page 7 INSTALLATION / ENLÈVEMENT DE LA GRILLE INSTALLATION / ENLÈVEMENT DU RÉFLECTEUR DE PROTECTION Un réflecteur droit RAR1 ou un réflecteur gauche RAL1 sont les modèles appropriés pour un luminaire à deux lampes. Les luminaires à Sallie de quatre lampes utilisent un RAR1 et un RAL1. retenue SUSPENSION Placer la grille de protection en acier inoxydable optionnelle sur le...
  • Page 8 REMPLACEMENT DES LAMPES Enlever le ballast et le support du montage du ballast en glissant le montage au complet à l'extérieur du boîtier du ballast. Couper l'alimentation électrique au luminaire. Installer le nouveau ballast en positionnant le support de montage Enlever le(s) réflecteur(s) et/ou l'écran (les écrans) de du ballast tel qu'illustré...
  • Page 9 ILLUMINATOR™ EVFT Luminaria Fluorescente IF 1143 Instructivo de Instalación y Mantenimiento CONSERVE ESTE INSTRUCTIVO PARA FUTURAS REFERENCIAS APLICACIÓN Las luminarias fluorescentes Illuminator son también adecuadas para uso en lugares húmedos, ambientes marinos y áreas de aplicación de Las luminarias fluorescentes Illuminator son adecuadas para uso en las pintura.
  • Page 10 MONTAJE COLGANTE ALAMBRADO ADVERTENCIA Todas las entradas para conduit de la luminaria deben estar selladas con tapones PLG's. Los tapones deben entrar manteniendo al menos 5 hilos completos en contacto. Use los tapones PLG a prueba de explosión suministrados con la luminaria. Conexión a tierra Remueva los soportes de montaje a techo y los tornillos del cuerpo...
  • Page 11 INSTALACIÓN / RETIRO DE LA GUARDA INSTALACIÓN / RETIRO DEL REFLECTOR Ranura de Ya sea un reflector derecho RAR1 o un reflector izquierdo RAL1 es retención apropiado para un conjunto de 2 lámparas. El conjunto de cuatro lámparas utiliza un RAR1 y un RAL1. COLGANTE Coloque la(s) guarda(s) de acero inoxidable opcional(es) sobre el ensamble del tubo de la lámpara deslizándolo sobre el tubo de...
  • Page 12 CAMBIO DE LAMPARA Utilizando un desarmador, afloje los tornillos en cada lado del soporte que asegura el balastro. Desconecte la corriente de la lámpara. Retire el balastro y su soporte de montaje deslizando el ensamble Remueva el (los) reflector(es) y/o los protectores de poli-carbonato completo fuera del porta balastro.