The typical charging time after a work shift of 8 – 10 h is
approx. 4 h.
The typical charging time for an empty battery is
approx. 10 h.
If the specified temperature range (5 to 35 °C) is not
reached or is exceeded, charging stops automatically.
This extends the charging time. After a return to the
temperature range, charging continues automatically.
The gas detector can be switched on again in the
charging cradle and is then supplied with electrical
current during operation.
WARNING
No measurement!
If there is an external power supply voltage drop > 1 s in
the charging tray while the gas detector is in operation,
the gas detector switches off.
► Ensure uninterrupted power supply. If this cannot be
insured, check at regular intervals to make sure that
the gas detector is switched on.
Designation and
description
Inductive charging cradle
for charging 1 gas detec-
tor
Adapter for the plug-in
1)
power supply unit
Plug-in power supply unit
for charging 1 gas detec-
tor
Plug-in power supply unit
for charging 5 gas detec-
tors
Plug-in power supply unit
100-240 V AC; 1.33 A for
charging up to 5 gas
detectors
(requires adapter
83 25 736)
Plug-in power supply unit
100-240 V AC; 6.25 A for
charging up to 20 gas
detectors
(requires adapter
83 25 736)
Instructions for use
|
X-am® 3500
Designation and
description
Vehicle connection
12 V / 24 V for charging
1 gas detector
Vehicle connection 12
V / 24 V for charging up to
5 gas detectors
(requires adapter
83 25 736)
Vehicle mount
(requires adapter
83 25 736 and vehicle
connection cable
83 21 855)
1) Contact Dräger for availability.

5.6 Cleaning

The gas detector does not require any special care.
If it is heavily soiled, wash the gas detector with cold
water and use a sponge if necessary. Use a cloth to dry
Order no.
the gas detector.
83 25 825
NOTICE
Damage to the gas detector!
Rough cleaning objects (e.g. brushes), cleaning agents
83 25 736
and solvent may destroy the dust and water filter.
► Only clean the gas detector with cold water and, if
83 16 997
6
83 16 994
Only trained and qualified personnel may change the

device settings.

83 21 849
For more details, refer to the technical manual.

6.1 Factory settings

Different settings can be selected to meet customer
83 21 850
requirements on order. The setting can be checked and
changed with the X-dock maintenance station or the
Dräger CC-Vision PC software.
Function
Fresh air calibration with-
out password
necessary, with a sponge.
Device settings
|
Device settings
Order no.
45 30 057
83 21 855
83 27 636
Setting
On
en