4.7.1.2 Opening the event report
The following events are counted and displayed: A1/A2,
STEL, shocks, incorrect password entries.
If the gas detector is switched off and then on again,
the event report is deleted.
To open the event report:
1. Select
> Info > Device information in measuring
mode.
2. Use ▲ or ▼ to scroll through the individual pages
until the event report.
The
symbol indicates a failed sign-on only after 5
attempts.
4.7.1.3 Activating the pump
To activate the pump in (normal) measuring mode:
1. Place, align and tighten the pump adapter on the
thread port on the top cover. Check that the pump
adapter is mounted correctly. Avoid bending the
pump adapter. The gas detector automatically
switches to pump mode as soon as the pump
adapter is mounted.
 The leak test starts automatically.
2. When the leak test is displayed, the suction inlet on
the probe or hose closes within 60 s and remains
closed until the leak test is complete.
3. Release the inlet opening.
● Leak test successful: Measurement starts.
● Leak test failed: Inspect the accessories and the
pump adapter and then repeat the leak test.
4. Observe the flushing times. For further information,
see the following chapter: "Special features when
measuring with the pump", page 32

4.7.2 Alarms

In the event of an alarm, corresponding displays, the
optical alarm, vibration alarm as well as, if necessary,
the acoustic alarm are activated (configurable). For
further information, see the following chapter: "Alarm
settings", page 39
To acknowledge an alarm:
1. Select
.
Instructions for use
|
X-am® 3500

4.7.3 Special state

The operation signal is deactivated during a special
state. Special states are displayed by the following
visual signals:
– Yellow LED flashing – 'warm-up 1' special state
– Yellow LED continuously illuminated – general
special state
No alarms are issued during a special state.
Exception: The calibration adapter is mounted in
measuring mode. In this case, alarms continued to be
issued as long as the measurement gas can reach the
sensors.
WARNING
Incorrect measurement!
A mounted calibration adapter blocks free gas diffusion
to the sensors. Correct measured values and alarms
can no longer be guaranteed.
► It is imperative to actively bump the sensors (e.g.
test gas cylinder with pressure reducer, flow
0.5 L/min).

4.7.4 Blocking alarm

The blocking alarm protects the CatEx sensor.
If the measuring range is exceeded significantly at the
CatEx channel (very high concentration of flammable
materials), a blocking alarm is triggered. This CatEx
blocking alarm can be acknowledge by switching the
gas detector off and then on again in fresh air.
For more details, refer to the technical manual.

4.7.5 Delete peak values

1. Select
in measuring mode and confirm the
dialog.
2. Select Clear app. peak and confirm the dialog.

4.8 Calling the Quick Menu

The Dräger CC-Vision software can be used to save up
to 6 preferred features.
The following features are default settings:
– Device information
– Switch between day and night mode
– Display messages
– Display shift peaks
|