Honeywell WT8840 Notice D'installation

Régulateurs de chauffe-eau de remplacement

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

WT8840
Trade Water Heater Controls
APPLICATION
The WT8840 Water Heater Control is designed for use
in Standing Pilot applications using an immersion well
for water temperature sensing. All models of WT8840
include an integrated NTC temperature sensor.
The WT8840 is powered from a thermopile heated by
the standing pilot flame. CS8840 pilot assemblies are
designed for use with this control.
The immersion well for sensing water temperature
has matched NTC thermistor sensors. These sensors
provide the fail-safe mechanism through which the
WT8840 can provide both accurate water
temperature control as well as water temperature
limit (Temperature Cut-Out [TCO]) function.
SPECIFICATIONS
IMPORTANT
WT8840 controls provide direct replacement only.
Pressure Regulator: The outlet pressure regulator
setting is shown on the product label.
Inlet Pressure Range:
See appliance rating plate for inlet pressure range
recommendation.
0.5 PSI (14.0 in. w.c.) maximum inlet pressure
allowed for proper operation.
Body Pattern: 90 degrees with 1/2 in. inlet and
1/2 in. inverted flare outlet.
Trade Service Part
WT8840A1000
1" insulation tank, 4" WC setting
WT8840A1500
2" insulation tank, 4" WC setting
WT8840B1000
1" insulation tank, 5" WC setting
WT8840B1500
2" insulation tank, 5" WC setting
* Includes pilot and combustion chamber gasket.
Replaces
OEM Part Number
WV8840A1000
222-47463-01A
WV8840A1001
222-47463-01E
WV8840A1050
222-47463-02A
WV8840A1051
222-47463-02E
WV8840B1042
316910-000
WV8840B1109
316910-000
WV8840B1110
321166-000
WV8840B1059
316910-001
WV8840B1117
316910-001
WV8840B1118
321166-001
INSTALLATION INSTRUCTIONS
Mounting: Mounting in upright position only.
Control Input:
Voltage Minimum: 350 mV dc, open circuit.
Voltage Maximum: 850 mV dc, open circuit.
Capacity: See Table 1.
Regulation Range:
Natural Gas:
Minimum: 30,000 Btuh.
Maximum: 85,000 Btuh.
Ambient Temperature Range: 32 to 150 °F (0 to 66 °C)
Operating Range: 0 to 150 °F (-18 to 66 °C)*
*Valve will operate at 0°F (-18°C) but valve
characteristics can not be guaranteed until
ambient temperature reaches 32°F (0°C).
Storage Range: -40 to 150 °F (-40 to 66 °C)
Humidity: 95% non-condensing at 104 °F (40 °C)
Approvals:
This device is certified by Canadian Standards
Association (CSA) to the following standards:
ANSI Z21.20
ANSI Z21.23
ANSI Z21.78
ANSI Z21.87
CAN/CSA-C22.2 No. 199-M89
CAN1-6.6-M78
CSA 4.6
CSA 6.20
Accessory Parts: Pilot Assembly CS8840
OEM Replacement
239-47463-01*
239-47463-02*
100112336 &
9007884005
100112337 &
9007885005
OEM
Bradford White
Bradford White
Bradford White
Bradford White
AOSmith
AOSmith
AOSmith
AOSmith
AOSmith
AOSmith
34-00013EF-03

Publicité

Table des Matières
loading

Sommaire des Matières pour Honeywell WT8840

  • Page 1 APPLICATION Mounting: Mounting in upright position only. Control Input: The WT8840 Water Heater Control is designed for use Voltage Minimum: 350 mV dc, open circuit. in Standing Pilot applications using an immersion well Voltage Maximum: 850 mV dc, open circuit.
  • Page 2: Planning The Installation

    High Humidity or Dripping Water M36122 Dripping water can cause the control to fail. Never Fig. 1. Typical capacity curve for WT8840 family install an appliance where water can drip on the water heater control system. control. In addition, high ambient humidity can cause the control to corrode and fail.
  • Page 3: Connect Gas Supply

    Always use a direct replacement sensor DROP TUBING assembly when replacing a temperature HORIZONTAL sensor. SUPPLY Location The WT8840 is mounted on the outside of the water heater tank. See Fig. 2. RISER 3 IN. (76 MM) MINIMUM MOUNTING WARNING WELL ASSEMBLY EXPLOSION HAZARD.
  • Page 4 WT8840 TRADE WATER HEATER CONTROLS Wiring IGNITION IMPERFECT SYSTEM Follow the wiring instructions furnished by the THREADS CONTROL appliance manufacturer, if available, or use the general instructions provided below. When these instructions differ from the appliance manufacturer, PIPE follow the appliance manufacturer instructions. Make sure wiring insulation does not get cut by sharp edges.
  • Page 5 Can damage electrical components in the WT8840. Do not spray soap and water solution on the WARNING WT8840 housing. Do not use an excessive amount of soap and water to perform the gas Fire or Explosion Hazard. Can cause severe leak test.
  • Page 6 WT8840 TRADE WATER HEATER CONTROLS main valve will not hold. When the status 4. Status indicator light should be in normal mode indicator goes out, the user can restart the (1 flash) with the knob in the PILOT position. system. (Approximate shutdown time is one Turn the device knob past the water temperature minute.)
  • Page 7 WT8840 TRADE WATER HEATER CONTROLS Troubleshooting Without Status Indicator Assistance Follow diagram in Fig. 6. TROUBLESHOOTING GUIDE WITHOUT STATUS LIGHT TURN DEVICE KNOB FROM OFF TO CHECK: PILOT, PRESS DOWN KNOB AND HOLD, • INLET PRESSURE LIGHT PILOT BY DEPRESSING PIEZO •...
  • Page 8: Turning Off The Appliance

    WT8840 TRADE WATER HEATER CONTROLS INSTRUCTIONS TO THE STOP: READ THE HOMEOWNER WARNINGS ABOVE. If the appliance does not turn on when the setpoint knob is set several degrees above the previous WARNING temperature, follow these instructions: Fire or Explosion Hazard.
  • Page 9: Régulateurs De Chauffe-Eau De Remplacement Wt8840

    NOTICE D'INSTALLATION APPLICATION Minimum : 30 000 Btuh. Maximum : 85 000 Btuh. Le régulateur de chauffe-eau WT8840 est conçu pour Plage de température ambiante : 0 à 66 °C les applications à veilleuse permanente utilisant un (32 à 150 °F) puits d’immersion pour la détection de la température...
  • Page 10 RÉGULATEURS DE CHAUFFE-EAU DE REMPLACEMENT WT8840 Numéro pièce de rechange Remplace Numéro FEO Remplacement FEO WV8840A1000 222-47463-01A Bradford White Réservoir, isolation de 1 po, 239-47463-01* colonne d’eau de 4 po WV8840A1001 222-47463-01E Bradford White WV8840A1050 222-47463-02A Bradford White Réservoir, isolation de 2 po, 239-47463-02* colonne d’eau de 4 po...
  • Page 11: Préparation De L'installation

    Fig. 1. Courbe de capacité typique pour le système régulateur. Si l’appareil se trouve dans une atmosphère de régulation de chauffe-eau de la gamme WT8840. humide, s'assurer que la circulation d'air autour du Tableau 1. Conversion des capacités de gaz pour le régulateur est suffisante pour éviter la condensation.
  • Page 12: Emplacement

    Toujours utiliser un capteur à remplacement direct pour remplacer le capteur de température. Emplacement 3 PO (76 MM) Le WT8840 se monte à l’extérieur du réservoir du MINIMUM chauffe-eau. Voir la Fig. 2. COLONNE DESCENDANTE ALIMENTATION MONTAGE...
  • Page 13: Remplissage Du Réservoir

    RÉGULATEURS DE CHAUFFE-EAU DE REMPLACEMENT WT8840 6. Retirer les dispositifs de protection de l’entrée et MISE EN GARDE de la sortie du régulateur de chauffe-eau, le cas échéant. Risque de contamination. 7. Connecter le tuyau à l’entrée et à la sortie du Peut causer un dysfonctionnement de régulateur du chauffe-eau.
  • Page 14: Allumage Du Brûleur Principal

    Couper Ne pas pulvériser de solution savonneuse sur aussi l’alimentation en gaz avant de le boîtier du WT8840. Ne pas utiliser une débrancher le manomètre et de réinstaller le quantité excessive de solution savonneuse bouchon. Recommencer le test de fuite de pour effectuer le test de fuite de gaz.
  • Page 15: Entretien

    RÉGULATEURS DE CHAUFFE-EAU DE REMPLACEMENT WT8840 ENTRETIEN DÉPANNAGE Dépannage à l'aide du voyant AVERTISSEMENT d'état Risque d’incendie ou d’explosion. Peut causer des dégâts et des blessures graves, voire 1. La veilleuse doit être allumée. Si ce n'est pas le mortelles.
  • Page 16 RÉGULATEURS DE CHAUFFE-EAU DE REMPLACEMENT WT8840 Tableau 3. Dépannage avec le voyant d'état. Code d’erreur du voyant Nombre de clignotements du voyant DEL Erreur détectée Action recommandée Fonc- 1 clignotement Pas une erreur; indique que Il est maintenant possible de tourner le bouton...
  • Page 17: Dépannage Sans L'aide Du Voyant D'état

    RÉGULATEURS DE CHAUFFE-EAU DE REMPLACEMENT WT8840 Dépannage sans l'aide du voyant d'état Suivre le schéma de la Fig. 6. GUIDE DE DÉPANNAGE SANS VOYANT D'ÉTAT VÉRIFIER : TOURNER LE BOUTON DE L'APPAREIL • PRESSION D’ENTRÉE D'ARRÊT À VEILLEUSE, LE MAINTENIR •...
  • Page 18: Instructions Au Propriétaire De La Résidence

    RÉGULATEURS DE CHAUFFE-EAU DE REMPLACEMENT WT8840 INSTRUCTIONS AU STOP! LIRE LES PROPRIÉTAIRE DE LA AVERTISSEMENTS CI- RÉSIDENCE DESSUS. Si l'appareil ne se met pas en marche quand le bouton AVERTISSEMENT du point de consigne est réglé à plusieurs degrés au- dessus de la température précédente, suivre ces...
  • Page 19 RÉGULATEURS DE CHAUFFE-EAU DE REMPLACEMENT WT8840 34-00013EF—03...
  • Page 20 RÉGULATEURS DE CHAUFFE-EAU DE REMPLACEMENT WT8840 Home and Building Technologies Aux États-Unis: Honeywell ® Marque de commerce déposée aux États-Unis 1985 Douglas Drive North © 2017 Honeywell International Inc. 34-00013EF—03 M.S. Rev. 04-17 Golden Valley, MN 55422 Imprimé aux États-Unis...

Table des Matières