Philips RESPIRONICS EverFlo Manuel De L'utilisateur page 19

Masquer les pouces Voir aussi pour RESPIRONICS EverFlo:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
EverFlo / EverFlo Q User Manual
G
M
uidanCe and
anufaCTurer
electromagnetic environment specified below. The user of this device should assure that it is used in such an environment.
i
T
MMuniTy
esT
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
Note 1: At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures,
objects, and people.
a: Field strength from fixed transmitters such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM
and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to
fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Device is
used exceeds the applicable RF compliance level above, the Device should be observed to verify normal operation. If abnormal performance is
observed, additional measures may be necessary, such as re-orienting or relocating the Device.
b: Over the frequency range 150 kHz to 80 MHz, the field strengths should be less than 3 V/m.
r
s
eCoMMended
eparaTion
d
:
The Device is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled.
eviCe
The user of the Device can help prevent electromagnetic interference by maintaining a minimum distance between portable and
mobile RF communication equipment (transmitters) and the Device as recommended below, according to the maximum output
power of the communications equipment.
r
M
o
aTed
axiMuM
uTpuT
p
T
ower of
ransMiTTer
(w
)
aTTs
0.01
0.1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be
estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter manufacturer.
Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from
structures, objects, and people.
18
'
d
- e
s
eClaraTion
ieC 60601 T
l
C
esT
evel
oMplianCe
3 Vrms
3 Vrms
150 kHz to 80 MHz
3 V/m
3 V/m
80 MHz to 2.5 GHz
d
p
isTanCes beTween
orTable and
s
eparaTion
150
h
80 Mh
k
z To
z
d = 1.2
0.12
0.38
1.2
3.8
12
i
leCTroMaGneTiC
MMuniTy
l
e
evel
leCTroMaGneTiC
Portable and mobile RF communications equipment should be
used no closer to any part of the device, including cables, than
the recommended separation distance calculated from the
equation applicable to the frequency of the transmitter.
Recommended separation distance:
d = 1.2
d = 1.2
80 MHz to 800 MHz
d = 2.3
800 MHz to 2.5 GHz
Where P is the maximum output power rating of the transmitter
in watts (W) according to the transmitter manufacturer and d is
the recommended separation distance in meters (m).
Field strengths from fixed RF transmitters, as determined
by an electromagnetic site survey a , should be less than the
compliance level in each frequency range b .
Interference may occur in the vicinity of equipment marked with
the following symbol:
M
rf C
obile
oMMuniCaTions
d
a
f
isTanCe
CCordinG To
requenCy of
(
)
MeTers
80 Mh
800 Mh
z To
d = 1.2
0.12
0.38
1.2
3.8
12
:
This device is intended for use in the
e
– G
nvironMenT
uidanCe
e
quipMenT and The
T
ransMiTTer
800 Mh
2.5 Gh
z
z To
d = 2.3
0.23
0.73
2.3
7.27
23
z

Publicité

Table des Matières
loading

Table des Matières