Velleman PI150BN Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

11. MAINTENANCE
Very little maintenance is required to keep your inverter operating smoothly. Clean
the exterior of the device periodically using a damp cloth in order to prevent the
accumulation of dust and dirt. Tighten the screws on the DC input terminals
whenever you are cleaning the device.
12. REMARK
All specifications are typical at nominal input voltage, 50% load and 25° C unless
otherwise noted. All specifications are subject to change without prior notice
WARNING : DO NOT DISASSEMBLE THIS DEVICE AS DOING SO MAY
CAUSE HAZARDOUS VOLTAGES !! RETURN THIS DEVICE TO THE DEALER
IN CASE OF TROUBLE !!
13. SPECIFICATIONS
DC input voltage
Output power
Output power surge
Battery-high shutdown
Battery-low alarm
Battery-low shutdown
Short circuit protection
No-load current
Alarm and thermal shutdown
DC input fuse
Dimensions (L x W x H)
Net weight
AC output voltage
Frequency
AC output socket
AC output socket
PI150W // 12V & 24V
DC 10-15V (12V) // DC 20-30V (24V)
150W
450W
15.5 ± 0.5V (12V) // 30 ± 1V (24V)
10.5 ± 0.5V (12V) // 21 ± 1V (24V)
10 ± 0.5V (12V) // 20 ± 1V (24V)
yes
< 0.3A
60° C ± 5° C
20A (12V) // 10A (24V)
165 x 91 x 58mm
0.85kg
230V
50Hz
PI150MN // PI15024MN
PI150BN // PI15024BN
6
VELLEMAN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pi150mnPi15024bnPi15024mn

Table des Matières