Lossnay
Models:
LGH-50RX
-CAN
3
LGH-100RX
-CAN
3
LGH-200RX
-CAN
3
Instruction manual for using and for installing the product.
(Instruction manual for the user, the dealer, and for the person qualified for the installation work.)
Please be sure to read carefully the supplied instruction manual before using and before installing the product.
Since this model LGH-50, 100, 200RX3-CAN is designed only for Canada, the sections "Safety precautions",
"Electric installation" and "Specifications" are partially different from the same sections included in the manual for
LGH-50, 100, 200RX3-E series
Safety precautions
WARNING
G This product must not be disassembled under any cir-
cumstances. Only authorized repair technicians are
No
qualified to conduct disassembly and repairs.
disassembly
(Failure to heed this warning may result in fire, electrical
shock or injury.)
G Do not install this product in a refrigerated warehouse,
heated swimming pool or other location where the tem-
Prohibited
perature and humidity are significantly different.
(Failure to heed this warning may result in electrical
shock or malfunctioning.)
G Do not install this product where it will be directly ex-
posed to the rain.
(Failure to heed this warning may result in electrical
shock or malfunctioning.)
G Do not install this product in a location where acid, alkali
or organic solvent vapors, paints or other toxic gases,
gases containing corrosive components or high con-
centrations of oily smoke are present.
(Failure to heed this warning may result not only in mal-
functioning but also fire, power leakage and electrical
shock.)
G Do not use this product outside the range of its rated
voltage and control capacity.
Single phase, 208-230V 60Hz
(Failure to heed this warning may result in fire or electri-
cal shock.)
G Install this product in an environment where the tem-
perature ranges from –10°C to +40°C and the relative
Instructions
must be
humidity is less than 80%. If condensation is expected
followed
to form, heat up the fresh outside air using a duct heater,
etc.
G Install this product in an environment where the outside
air intake meets the following conditions: temperature
range is between –10°C and +40°C and the relative
humidity is 80% or less.
G Using Pre-Heat Unit
• Make sure to install Pre-heat unit where outdoor air
temperature is below –10˚C, or condensation is
expected to form.
• Pre-heat unit must be installed from Lossnay unit as
far as possible, because of fire prevention.
• Select and operate Pre-heat unit that Lossnay supply
intake air temperature becomes between –10˚C to
40˚C.
• Pre-heat unit must be controlled to stop during
Lossnay not operating.
G Select a position for introducing the outside air where
no exhaust or combustion gases will be sucked into
the product and where it will not be covered by snow.
(Failure to ensure a supply of fresh air can result in pro-
ducing a state of oxygen deficiency inside the room.)
G Select an adequately sturdy position for installing the
product and install it properly and securely. (Injury may
result if the product should fall.)
G Use the designated electrical wires for the terminal board
connections, and connect the wires securely so that
they will not become disconnected.
(Failure to ensure proper connections may result in fire.)
G When passing metal ducts through wooden buildings
clad with metal laths, wire laths or metal, these ducts
must be installed in such a way that they will not make
electrical contact with the metal laths, wire laths or metal
sheets. (Power leakage can cause ignition.)
G The outside ducts must be tilted at a gradient (1/30 or
more) down toward the outdoor area from Lossnay unit,
and properly insulated.
(The entry of rain water may cause power leaks, fire or
damage to household property.)
G Gloves should be worn when doing the installation work.
(Failure to heed this warning may result in injury.)
G A dedicated circuit breaker must be installed at the ori-
gin of mains power supply. This circuit breaker must be
provided with a means for locking (lock and key).
G Connect the product properly to ground.
(Malfunctioning or power leaks can cause electrical
Connect the
shock.)
grounding wire.
G An isolator switch having a minimum contact gap of 3
mm in all poles must be provided as a means of dis-
connecting the power supply.
0406873HG4901
1

Publicité

Table des Matières
loading

Sommaire des Matières pour Mitsubishi Electric Lossnay LGH-50RX3-CAN

  • Page 1 0406873HG4901 Lossnay Models: LGH-50RX -CAN LGH-100RX -CAN LGH-200RX -CAN Instruction manual for using and for installing the product. (Instruction manual for the user, the dealer, and for the person qualified for the installation work.) Please be sure to read carefully the supplied instruction manual before using and before installing the product. Since this model LGH-50, 100, 200RX3-CAN is designed only for Canada, the sections “Safety precautions”, “Electric installation”...
  • Page 2: Electrical Installation

    Electrical installation With this product, the wiring installation method will vary according to the design of the system. Perform electrical installation for each of the required sections. Names of components in control box LGH-50 and 100 RX LGH-200 RX Earth pole LED4 LED1 LED2...
  • Page 3: Connecting The Power Supply Cable

    Wire connection diagram ----- Models LGH-200 RX Connect the wires shown as dotted lines. Be sure to connect the grounding wire. Breaker should be provided by the customer. Symbol explanation TH1 (OA) TH2 (RA) Motor for exhaust fan Motor for supply fan BROWN Capacitor (CN16)
  • Page 4 28-30 34-37 Extra High 5.7-5.7 1200-1290 2000 11.7-20.4 115-200 39-41 50-52 LGH- 1-Phase High 5.1-5.1 1058-1161 1800 9.2-16.3 90-160 37-39 47-49 200RX -CAN 208 - 230 3.3-3.4 682-786 1250-1350 347-375 4.6-9.2 45-90 79-78 74-73 56-55 30-32 39-41 MITSUBISHI ELECTRIC CORPORATION...
  • Page 5: Consignes De Sécurité

    Lossnay Modèles: LGH-50RX -CAN LGH-100RX -CAN LGH-200RX -CAN Manuel d’utilisation et de montage (Pour l’acheteur, le revendeur et le monteur qualifié) Nous vous recommandons de lire le manuel d’utilisation et de montage fourni avec l’appareil. Le modèle LGH-50, 100, 200RX3-CAN étant exclusivement destiné au Canada, les paragraphes « Consignes de sécurité...
  • Page 6: Travaux Électriques

    Travaux électriques Sur cet élément, la méthode de câblage diffère selon la conception du système. Effectuer les travaux électriques pour chacune des sections requises. Noms des éléments du boîtier de commande LGH-50 et 100 RX LGH-200 RX Piquet de terre LED4 LED1 LED2...
  • Page 7: Raccordement Du Câble D'alimentation

    Schéma de câblage ----- Modèles LGH-200 RX Brancher les fils représentés par des lignes en pointillés. Veiller à toujours raccorder le fil de terre. Explication des symboles Le disjoncteur doit être fourni par le client. Moteur pour le ventilateur d’évacuation de l’air TH1 (OA) TH2 (RA) Moteur pour le ventilateur de...
  • Page 8: Travaux Électriques (Suite)

    34-37 Très fort 5.7-5.7 1200-1290 2000 11.7-20.4 115-200 39-41 50-52 LGH- 1-Monophasée Fort 5.1-5.1 1058-1161 1800 9.2-16.3 90-160 37-39 47-49 200RX -CAN 208 - 230 faible 3.3-3.4 682-786 1250-1350 347-375 4.6-9.2 45-90 79-78 74-73 56-55 30-32 39-41 MITSUBISHI ELECTRIC CORPORATION...

Ce manuel est également adapté pour:

Lossnay lgh-100rx3-canLossnay lgh-200rx3-can

Table des Matières