Installation Instructions; Tools And Parts; Location Requirements; Required Cutout Dimensions - Whirlpool MK2167 Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Tools and Parts

Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Measuring tape
Pencil
Phillips screwdriver
Parts Supplied (not shown to scale
Rails (2)
Bottom duct
Short screws (14)
(11 + 3 extra)

Location Requirements

The microwave oven may be installed over a built-in oven. If
installing over a built-in oven, make sure there is a minimum of 3"
(7.6 cm) between the top of the lower oven cutout and the
microwave oven cutout floor.
The microwave oven may also be installed in a cabinet by itself
(without a built-in oven below). For best usability, we recommend
a minimum distance of 36" (91.4 cm) from the floor to the cutout
floor.
Make sure the surrounding cabinetry has clearance to open and
close freely. Allow a clearance of at least 1⁹⁄₁₆" (4.0 cm) below the
cutout floor (3" [7.6 cm] for installation above a built-in oven), and
a clearance of at least 2" (5.1 cm) above the cutout opening.
2"
(5.1 cm)
B
⁹⁄₁₆
1
"
(4.0 cm)
D
E
A. Upper cabinet
B. Microwave oven cutout
C. Lower oven cutout
2

INSTALLATION INSTRUCTIONS

Drill
7/64" drill bit
Trim kit frame
Long wood screws (6 - painted)
(4 + 2 extra)
A
B
C
36"
(91.4 cm)
D. Lower cabinets
E. Floor

Required Cutout Dimensions

For minimum depth requirements, see chart.
17" (43.2 cm)
min.
¹⁄₈
17
" (43.5 cm)
max.
3"
)
(7.6 cm
A. Trim kit frame overhang
B. Cutout for lower oven
C. Recommended region for receptacle
D. Cutout centerline
Receptacle Location
Within recommended
region
Outside recommended
region
NOTES:
Depth requirements depend upon receptacle and its location
within or outside of recommended region. See illustration and
chart above.
Height dimension is critical: 17" (43.2 cm) minimum, 17¹⁄₈"
(43.5 cm) maximum.
Width measurement has ±1/16" (2 mm) tolerance.
3" (7.6 cm) minimum dimension is from lower oven cutout
ceiling to microwave oven cutout floor.
Trim kit frame extends 1¹⁄₁₆" (2.7 cm) above and below the
cutout opening.
2"
(5.1 cm)
3"
(7.6 cm)
6"
(15.2 cm)
¹⁄₈
23
" (58.7 cm)
D
C
location (no less than 6" [15.2 cm] to
the right of cutout centerline)
Minimum Depth
18" (45.7 cm) with flush receptacle;
21" (53.2 cm) with non-flush receptacle
19¹⁄₂" (49.5 cm) with flush receptacle;
22¹⁄₂" (57.2 cm) with non-flush
receptacle
¹⁄₁₆
1
"
(2.7 cm)
A
¹⁄₁₆
1
"
(2.7 cm)
B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mk2160Umc5165as

Table des Matières