Technical data

Dimensions:
Weight:
with battery, 24 Ah
Ambient conditions:
During operation
During storage
Alarms:
Visual, 360° LED
Audible, 360°
Battery:
Operating time, 24 Ah
(20 °C)
Charging time, 24 Ah
Charging input XEXT1:
(Ex limits):
XEXT3 external power
supply:
Max. input voltage:
Max. input current:
Max. input power:
Max. internal capacity:
Max. internal inductivity:
Pump:
Coupling of
devices:
Dräger X-zone 5500 / 5800
approx. 490 x 300 x 300 mm
(H x W x D)
approx. 10 kg
-20 °C to +50 °C
-20 °C to +70 °C
700 to 1300 hPa
max. 95 % relative humidity
green life signal;
red alarm signal;
green/red secondary alarm
108 dB (A) at 1 m distance
120 dB (A) at 30 cm distance
120 hours at 15 minutes per day
and fully equipped X-am 5x00
<14 hours
U = 15 V, nominal
I
= 2.5 A, nominal
U
= 30 V
m
I
= 10 A
m
Ui-1, Ui-2, Ui-3, Ui-4 = 13.10 V
Ii-1, Ii-2, Ii-3, Ii-4 = 0.85 A
Pi-1, Pi-2, Pi-3, Pi-4 = 2.78 W
Ci-1, Ci-2, Ci-3, Ci-4 = 1 nF
Li-1, Li-2, Li-3, Li-4 = 1 µH
Only connect galvanically isolated,
intrinsically safe electric circuits
with limited internal resistance.
up to 30 m of hose
0.5 L/min
Up to 25 devices can be
connected
on
a
network.
Combined
wireless/cable
operation possible.
Switchable
frequencies
DrägerService) with a typical
range of 100 m in industrial
surroundings
(environmental
factors may affect the range).
Automatic
establishment
wireless connection.
Relay output:
Max. voltage (U
Max. switching current (I
Max. continuous current:
Max. switching capacity
(P
):
i
For ohmic loads only!
Reactances
No connection with:
Approvals:
Serial no. (year of
construction)
Detection range:
Induction charger:
Input
Output
Charging with
wireless
Level of contamination
Overvoltage category
(by
Protection class
of
):
20 V
i
):
0.25 A
i
0.25 A
3 W - For ohmic loads only!
C
negligible;
i
L
negligible
i
Capacitive or inductive
loads
The approvals are shown on the
rating plate.
The year of construction is given by
the 3rd letter in the factory number
located on the nameplate:
M=2019, N=2020, P=2021,
R=2022, S=2023, T=2024,
U=2025, W=2026, X=2027,
Y=2028, Z=2029, etc. (G, I, O, Q
have been omitted)
Example: Serial number
ARMH-0054, the 3rd letter is M, so
the year of manufacture is 2019.
see the Dräger
Technical Handbook X-am 5x00
100 to 240 V/50 to 60 Hz 40 W
15 V/2 A
0 °C to +40 °C
max. 95% relative humidity
2
II
IP 40
Technical data