Technical data

16
Technical data
Dimensions:
Weight:
with battery, 24 Ah
Ambient conditions:
During operation
During storage
Alarms:
Visual, 360° LED
Audible, 360°
Battery:
Operating time, 24 Ah
(
20 °C)
Charging time, 24 Ah
Charging input XEXT1:
(Ex limits):
Pump:
Coupling of
devices:
Relay output:
Max. voltage (U
):
i
Max. switching current (I
):
i
Max. continuous current:
Max. switching capacity (P
i
):
For ohmic loads only!
Reactances
No connection with:
72
approx. 490 x 300 x 300 mm
(H x W x D)
approx. 10 kg
-20 °C to +50 °C
-20 °C to +70 °C
700 to 1300 hPa
max. 95% relative humidity
green life signal;
red alarm signal;
green/red secondary alarm
108 dB (A) at 1 m distance
120 dB (A) at 30 cm distance
120 hours at 15 minutes per day
and fully equipped X-am 5x00
< 14 hours
U = 15 V, nominal
I
= 2.5 A, nominal
U
= 30 V
m
I
= 10 A
m
up to 30 m of hose
0.5 L/min
Up to 25 devices can be
connected
on
a
wireless
network.
Combined
wireless/cable
operation possible.
Switchable
frequencies
DrägerService) with a typical
range of 100 m in industrial
surroundings
(environmental
factors may affect the range).
Automatic establishment of
wireless connection.
20 V
0.25 A
0.25 A
3 W - For ohmic loads only!
C
negligible;
i
L
negligible
i
Capacitive or inductive
loads
Approvals:
Serial no. (year of
construction)
Detection range:
Induction charger:
Input
Output
Charging with
Level of contamination
Overvoltage category
Protection class
(by
The approvals are shown on the
rating plate.
The year of construction is given
by the 3rd letter in the factory
number located on the nameplate:
B=2010, C=2011, D=2012,
E=2013, F=2014, G=2015,
H=2016, etc.
Example: Serial number ARFH-
0054, the 3rd letter is F, so the
year of construction is 2014.
see the Dräger
Technical Handbook X-am 5x00
100 to 240 V/50 to 60 Hz 40 W
15 V/2 A
0 °C to +40 °C
max. 95% relative humidity
2
II
IP 40
Dräger X-zone 5500