Velleman DCM120 Mode D'emploi page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
Pollution
Conductive pollution occurs, or dry nonconductive pollution
degree 3
occurs that becomes conductive due to condensation that is
to be expected. (industrial environments and environments
exposed to outside air - but not in contact with precipitation)
Pollution
The pollution generates persistent conductivity caused by
degree 4
conductive dust or by rain or snow. (exposed outdoor
environments and environments where high humidity levels
or high concentrations of fine particles occur)
Warning: This device was designed in accordance with EN 61010-1
pollution degree 2. This implies that certain restrictions in use apply that
are related to pollution which can occur within the environment of use. Refer
to the table above.
This device is only suitable for measurements in Pollution
degree class 2 environments.
9. Specifications
This device is not calibrated when purchased!
Regulations concerning environment of use:
Use this meter only for measurements in CAT I, CAT II and CAT III
environments (see §7).
Use this meter only in a pollution degree 2 environment (see §8).
Ideal working conditions include:
temperature: 0 °C to 40 °C (32 °F to 104 °F)
relative humidity: max. 80 %
altitude: max. 2000 m (6560 ft)
IP rating ........................................................................... IP20
voltage ........................................................................... 600 V
power supply ....................................... 3 x 1.5 V AAA/LR03 (incl.)
display ............................................................ LCD, 1999 counts
display dimensions ................................................... 24 x 37 mm
over-range .......................................................................... yes
continuity buzzer .................................................................. yes
diode test ............................................................................ yes
low-battery indication ........................................................... yes
ranging mode ......................................................... auto/manual
data hold ............................................................................ yes
backlight ............................................................................. yes
auto power-off ..................................................................... yes
dimensions ..................................................... 194 x 72 x 35 mm
weight (with battery) ......................................................... 230 g
storage environment
temperature ................................................. -20 °C to 60 °C
humidity ............................................................ < 90 % RH
test lead probe ....... CAT III 1000 V / CAT IV 600 V, 10 A; L = 84 cm
V. 04 – 25/02/2020
DCM120
8
©Velleman nv

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cat iii 600 v