Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
9.4 RESISTANCE
range
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
20 MΩ
Overload protection: 250 V DC or AC rms
9.5 DIODE + AUDIBLE CONTINUITY
range
Overload protection: 250 V DC or AC rms
9.6 TEMPERATURE
range
resolution
accuracy
range
resolution
accuracy
Overload protection: 250 V DC or AC rms
V. 04 – 25/02/2020
Do not conduct resistance measurements on live circuits
resolution
0.001 kΩ
0.01 kΩ
0.001 MΩ
0.01 MΩ
Do not conduct diode and continuity measurements on
displays approx. forward voltage of the diode, reverse
built-in buzzer sounds if resistance < 30 Ω
-20 °C - 0 °C
0 °C - 400 °C
400 °C - 1000 °C
0 °F - 50 °F
50 °F - 750 °F
750 °F - 1800 °F
DCM120
0.1 Ω
0.1 kΩ
live circuits
function
shows OL
-20 °C - 1000 °C
1 °C
0 °F - 1800 °F
1 °F
10
accuracy
± (1.0 % + 10)
± (0.8 % + 5)
± (2.0 % + 10)
± (5.0 % + 4)
± (2.0 % + 3)
± (3.0 % + 3)
± (5.0 % + 4)
± (2.0 % + 3)
± (3.0 % + 3)