Technical data

12
Technical data
Ambient conditions
Operation:
Temperature
Air pressure
Relative humidity
Type of protection
Storage:
Temperature
Air pressure
Relative humidity
Performance data
Measuring range, resolution
Measuring volume
Measuring time
Readiness for use
Intoxication effect
Calibration
Sample flow
Analyzer data
Light source
Acquisition of measured values
Barcode reader
System diagnosis
Display
User guidance
Menu languages
Operating time
Power supply
For analyzer set (order no. 6405300):
Material Analyzer housing
62
1)
0 to 40 °C
700 to 1100 hPa
0 to 95 %
without condensation
IP 54
–20 to 60 °C
700 to 1100 hPa
0 to 95 %
Depends on type of chip being used
Max. 30 mL in 2 min. measuring time
Between 20 seconds and 3 minutes,
depending on the concentration of the gas or vapour
and on the type of chip being used
Between 20 seconds and 10 minutes in the case of
special hazardous gases
Immediate
Not possible
By manufacturer
7.5 to 15 mL/min,
electronically controlled
LEDs
Six-fold optical system and waveguides,
reflectance measurement
Six-channel optical system
Automatic with microcontroller for all system
components
LCD, 2 x 16 characters,
alphanumerical, with backlighting
Plain text with LCD and buzzer
English, German, French, Spanish
Approx. 450 measurement minutes
4 x 1.5 V batteries.
Only the following types may be used:
Ralston (Energizer) Alkaline LR6
Duracell MN 1500 LR6
Rayovac
(Only in conjunction with a charger:
Rayovac Charger PS1 or PS3)
Glass-fibre-reinforced polyamide
Rechargeable Alkaline AA
Dräger CMS Analyzer