4.4 Commissioning
Open the water intake and switch on the terminal equipment's power supply.
•
G
Operate the flush valve
•
without bubbles. At least two empty filter cartridge volumes must be flushed ( C hapter 9).
H
Note: When bleeding/flushing, catch water emerging from the flush hose
a ppropriate container.
Check system for any leaks.
•
5 Changing the filter cartridge
The PURITY C filter cartridge must be replaced once the stated capacity has been reached
(see Chapter 6), in accordance with manufacturer´s specifications or no later than 12 months after
commissioning, whichever occurs first.
Caution: When changing a filter cartridge, examine all remaining parts carefully! Faulty parts
!
must be exchanged and contaminated parts should be cleaned. Read the operating and safety infor-
mation (Chapter 3) before changing the cartridge. After storage and transport below 0 °C (32 °F) the
product must be stored in the open original packaging for at least 24 hours before it is commissioned
at the stated ambient temperatures (Chapter 9) for operation.
Note: When the locking handle is open, the water supply to the cartridge is interrupted and short-
circuit operation with direct water flow from the water inlet
(if necessary, close the water intake and switch off the power supply to the terminal equipment).
Open locking handle
•
Activate the flush valve
•
Remove exhausted filter cartridge
EN
•
tridge. Note: The filter cartridge can be pivoted by 90 ° in the wall mounting bracket for easy removal.
Perform the steps described at 4.3 and 4.4.
•
6 Bypass and capacity tables
The capacity tables for the PURITY C filter systems are provided on pages 2–5. The capacities
shown in the capacity tables are based on German carbonate hardness and are not certified by NSF.
Note: The stated capacities were tested and calculated based on standard application and machine
conditions. This information may vary according to external influencing factors.
The PURITY C1000 AC has a filter capacity of 10,000 litres, regardless of the carbonate hardness
and the bypass set. All intake water is filtered.
For PURITY C1100 XtraSafe please use the VIVREAU Professional Filter website for individual
capacity calculation:
Please go to the capacity calculation on the website
•
https://vivreauwater.com/products/purity-c1100-xtrasafe/
Enter locally measured Carbonate Hardness, Total Hardness and Conductivity
•
•
Important: Set the by-pass accordingly, track the individually calculated capacity
and change the cartridge in time!
14
and flush the filter system until the filtered water runs clear and
8
.
2
and depressurise the system.
8
from the filter head
6
to the water outlet
4
3
, bearing in mind the weight of the car-
1
in an
9
is possible